experience9 yearsRuslan Ts.
Washing machine and refrigerator repair technician
City
Language
What broke
Sections
Message on WhatsApp+7 (775) 030 02 94Mon–Fri 10:00–19:00, Sat–Sun 11:00–18:00
A technician arrives within 60 minutes anywhere in the city. Free diagnostics.
Our own technicians4 to 20 years of experience




Repair prices
Pick the closest symptom to describe your situation more accurately when you request service. The technician pinpoints the cause after diagnostics.
piezo ignition, gas valve, control board
from6 000 ₸
three-way valve, heat exchanger
from7 500 ₸
the code points to a component, not the whole fault
from5 500 ₸
pump, air in the system, scale
from7 500 ₸
hoses, pump, seals
from10 500 ₸
make-up, expansion tank, leak
from7 500 ₸
draft, flame sensor, gas valve
from6 000 ₸
three-way valve, control board, sensor
from7 500 ₸
The table lists the 'from' price for labor, for common jobs also the 'from' price of the part, plus the time required to complete the job.
1 visittime
from 10 500 ₸cost

BeforeAfter5 steps

From your request to checking the boiler's operation.
Describe the symptom and boiler model so the technician brings the right tools.
The technician brings tools for the described symptom and model, and clarifies the fault history on site.
Tell the technician the error code and when the symptom appears, then ask about the cause and the work plan.
Confirm the agreed list of work and ask about the warranty terms for the repair.
When the boiler starts after repair, check that it runs steadily and ask the technician any questions before they leave.
The home appliance repair department in Almaty has 8 technicians with 8 to 12 years of experience.

The department has 8 specializations — they are listed on the technicians' cards.
experience9 yearsWashing machine and refrigerator repair technician
experience12 yearsGeneral household appliance repair technician
experience10 yearsField technician for washing machine and refrigerator repair
experience8 yearsExpert washing machine repair technician
experience8 yearsField refrigerator repair technician
experience8 yearsSenior washing machine repair technician
experience11 yearsDishwasher repair technician
experience9 yearsWashing machine repair technician
We reply during working hours
Choose a convenient visit time and make sure the boiler and ventilation are accessible. Ask the technician in advance which tools and parts will be needed.

Warranty question? Call us
+7 (775) 030 02 947 898 reviews of repairs at TECH SERVICE in total
Айнур М.Order No. TS-2735 · 8 July 2026
oursБыло подозрение, что дело в плате, хотелось услышать второе мнение. Второй месяц — полёт нормальный.
Куаныш Б.Order No. ZK-6834 · 16 December 2025
oursБыло важно, чтобы сделали до выходных — гости, то-сё. С чем пришёл: не греет воду. Починили и дали гарантию на месяц.
Елена К.Order No. TS-8372 · 9 March 2025
oursПовод для визита: не зажигается. Дамир М возился с этим дольше, чем планировал, но довёл до конца. Починили и дали гарантию на месяц.
Владимир Н.Order No. 84104 · 6 May 2023
oursДруг посоветовал, у него похожая история была. Честно, уже готовился покупать новое, но обошлось. Повод для визита: не греет воду. Никита М помог выбрать, без навязывания. Запчасть была в наличии, доплачивать не пришлось. Приехал без записи, приняли как есть. Под замену пошло: мембрана. В помещении тесновато, но это мелочи. Работает даже тише, чем до поломки
Мирас С.Order No. ZK-5244 · 24 November 2022
oursТехника на гарантии уже не была, так что выбор был свободный. Вернули в тот же день, всё функционирует
Игорь Щ.Order No. ZK-2022/184 · 8 June 2022
oursДо этого обращался в другой сервис, там только развели руками. Честно, уже готовился покупать новое, но обошлось. С чем пришёл: течёт. Могли бы взять больше, но взяли по-божески. В списке работ — мембрана. Созвонились, договорились на удобное время, никто не тянул. Хороший сервис, побольше бы таких. Гудит ровно, не грееться, всё как надо.
Айнур М.Order No. 2022-1316 · 28 April 2022
oursДолго откладывал ремонт, потом всё-таки собрался. Долго искал, кому это отдать, и вот нашёл. Жалоба простая: течёт. Поменяли: насос. Заявку приняли по телефону, перезвонили через десять минут. Проверил дома — всё на месте, ничего не забыли
Сабина Г.Order No. ZK-7520 · 4 October 2020
oursТехниканы жөндеуге алып келу үшін арнайы уақыт бөлдім. Техника кенеттен істен шықты, қатты асығыс едім. Достарыма да айттым.
Вероника П.Order No. 2019-7397 · 21 July 2019
oursБольше всего напрягало: не греет воду. Дамир М возился с этим дольше, чем планировал, но довёл до конца. Сказать, что доволен — ничего не сказать.
Тимур И.Order No. 2018-4806 · 30 September 2018
oursБағасын алдын ала айтты, артынан қосымша талап етпеді. Мастер ақауды түсіндірді, қажетсіз нәрсе таңбады. Бағасын алдын ала келістік, соңында өзгерген жоқ. Диагностика тегін болды, бұл жағы жақсы. Кәсіби мамандар, рақмет.
Didn’t find the answer? Message us on WhatsApp.
Ask a questionOwners tend to praise Kiturami for efficiency and simple controls, but criticize sensitivity to water and gas quality. Reviews vary by model and operating conditions, and the most objective indicator of reliability is how the boiler holds up after several seasons.
There's no clear winner: Navien and Kiturami are in the same class but handle local conditions differently. Kiturami is often chosen for repairability and parts availability, while Navien for wider service coverage, so the choice depends on the model and your needs.
For a private home, a floor-standing boiler is chosen based on area, combustion chamber type, and local service availability. Among floor-standing models, Kiturami is valued for its cast-iron heat exchanger and repairability, but it's best to confirm the specific model with a technician after inspecting the house.
Most often it goes out due to weak draft, a clogged burner, or a faulty flame sensor. It depends on the model, and a technician will pinpoint the exact cause during free diagnostics.
The board usually causes random errors and component malfunctions, while a sensor gives a specific repeating code or incorrect readings. You can only tell them apart by measuring signals, so a technician's diagnostics are needed.
Most Kiturami breakdowns are fixed right on-site by a technician, including sensor and burner replacement. The boiler is only taken to a service center for complex board repairs, depending on the model and the nature of the fault.
Tech Service repairs Kiturami gas boilers in Almaty at your home and at the service center with its own technicians who have 4 to 20 years of experience. Diagnostics are free, a technician arrives within 60 minutes anywhere in the city, and we provide a 1-year warranty on labor and parts. We quote the price after diagnostics.
A code on the display is not a verdict but a hint about which component to check first. We break down common Kiturami errors, their meaning, and what the owner should do for each.
An error code on a Kiturami boiler points to a component that has gone beyond acceptable parameters, not to a part that needs replacing. The electronic control board monitors ignition, the pump, and valves by polling NTC sensors, the pressure switch, and ionization electrodes, and when a signal goes out of range, it records the fault number. The same number can be triggered by the sensor itself, the board, or damaged wiring to it—the signal is the same, but the cause for each of the three different elements is different. That's why the interpretation is always confirmed by measuring resistance, checking contacts, and testing the circuit, not by replacing parts "by code." If the code repeats, it makes sense to schedule Kiturami gas boiler repair in Almaty right away rather than replacing parts at random. In my opinion, the most common mistake owners make is buying a part based on the error number and not solving the problem: the board is fine, but the culprit is a corroded connector.
| Code | What it means | Which component | Owner's action |
|---|---|---|---|
| E01 | No flame on ignition | Ignition electrodes, gas valve | Don't reset repeatedly; call a technician |
| E02 | Flame goes out during operation | Ionization electrode, draft | Check if the gas valve is open |
| E03 | Heat carrier overheating | NTC sensor, circulation | Let it cool down, check system pressure |
| E04 | No flow signal | Flow sensor, pump | Open all hot water taps, reset |
| E05 | Flue draft failure | Pressure switch, fan | Check if the flue is frozen |
| E06 | Temperature sensor error | NTC sensor, wiring | Reset once; if it repeats, call a technician |
| E07 | Control board problem | Board, contacts | Don't reset; diagnostics needed |
We consider a button reset acceptable only for one-off power or gas pressure glitches; everything else requires checking the component. Voltage surges in the grid damage the boiler's electronic board, and after a spike the unit may go into error without a real breakdown—a restart will clear it. It's a different story when, after a reset, the boiler runs a cycle and goes back into the same error: the issue is not the electronics but the component that the board correctly locked out. The gas valve, a clogged NTC sensor, or lost draft won't fix themselves, and each new reset only delays a specialist's visit. A Tech Service technician during free diagnostics measures the component's parameters and confirms the cause rather than repeating the reset. If the code comes back a second time in a row, don't wait for a third.
We break down common complaints from Kiturami owners and show which component is behind each. We also explain why the same breakdowns occur more often in our city than in regions with soft water and a stable grid.
If the heating works but there's no hot water, the three-way valve, flow sensor, or a clogged secondary heat exchanger is usually to blame. The Kiturami three-way valve switches the flow between the heating circuit and the hot water circuit: if the stem is corroded, it gets stuck in the 'heating' position and doesn't let water through. The flow sensor (turbine) gets clogged with small debris and stops sending a signal to the board — the boiler simply doesn't detect water draw. The secondary heat exchanger, made of thin plates, gets clogged with scale and loses heat transfer: the burner heats, but the water at the outlet is barely warm. Another cause is air in the hot water circuit after a long summer break, when air prevents water from passing through the heat exchanger. Scale in the hot water circuit narrows the passage faster than in the heating circuit because fresh hard water constantly flows through it — flushing the secondary circuit should be planned earlier than flushing the heating system. If self-flushing doesn't help, it's better to entrust Kiturami gas boiler repair in Almaty to a technician with experience specifically on these models.
| Symptom | Likely component | Cause | What the technician checks |
|---|---|---|---|
| Burner goes out after a minute | Ignition electrodes | Carbon buildup, incorrect gap | Gap and cleanliness of electrodes |
| Burner goes out during operation | Gas fittings | Pressure surge in the network | Gas pressure at the inlet |
| Pressure gauge needle drops | Expansion tank | Pressure loss in the air chamber | Pressure in the tank, valve |
| Pressure fluctuates during heating | Expansion tank | Ruptured diaphragm | Integrity of the diaphragm |
| Humming and vibration of the pump | Circulation pump | Air in the system, bearing wear | Air, rotor rotation |
| Noise in the heat exchanger | Heat exchanger | Scale on the walls | Degree of clogging |
In Almaty, we see three main reasons for service calls — hard water, seasonal gas pressure fluctuations, and voltage surges in the network. Hard water leaves scale on the heat exchanger walls: the layer grows, heat transfer drops, the burner works under overload, and the component fails faster. Seasonal gas pressure fluctuations in the city network disrupt a stable flame: the burner goes out, and the ignition electrodes get fouled from frequent ignition attempts. Voltage surges hit the electronics — the Kiturami control board is sensitive to network spikes, and in private sectors and old buildings they happen regularly. These three factors most often lead to a service call: the same model in a home with a stabilizer and water softener lasts noticeably longer between maintenance. Prevention targeting these three factors extends the boiler's life more than any one-time part replacement after a breakdown — a stabilizer and regular circuit flushing are cheaper than a control board or heat exchanger.
We show the path from request to checking the unit in operating mode: what the specialist focuses on first, how work with wall-mounted and floor-standing models differs, and what work is done on site.
Our diagnostics start with the boiler's operating sequence — ignition, reaching temperature, switching to hot water — not with taking units apart. The technician starts the unit, listens to the burner, checks the pressure gauge and how the flame behaves when switching between modes, then inspects the gas fittings, the three-way valve and the pressure in the circuit. Each mode is tested separately: heating, water heating, and operation at minimum power — that's usually where the fault hides. This order rules out false leads: if the unit completes a full cycle, the problem is in a specific mode, not the board as a whole. We only inspect components after we've seen the picture in action. Diagnostics are free, so the owner gets an exact list of faults before any work begins, and the technician quotes the price after the inspection.
The wall-mounted Kiturami is more compact and tightly packed, while the floor-standing one gives easier access to the burner and heat exchanger but is heavier due to its components. In wall-mounted models, the hydraulics, three-way valve and sensors sit in a tight block, so any leak or clog quickly affects hot water performance. Floor-standing models have a larger combustion chamber, and the burner area more often suffers from carbon buildup and poor draft. The floor-standing heat exchanger is more massive and holds heat longer, but takes more time to flush. Floor-standing units more often lose efficiency due to burner contamination, while wall-mounted ones suffer from hydraulic wear in the tight layout. Before the visit, specify the model: it determines which tools and consumables the technician brings.
We do most Kiturami work on-site; we only take the unit to the service center when a component needs to be disassembled or the board needs component-level repair. A technician arrives within 60 minutes in the city and checks the unit together with the heating system: sometimes the cause is air in the system, a clog in the circuit or incorrect settings, not a failure of the unit itself. Such cases are resolved without replacing parts. If component-level board repair is needed, the board is removed and restored separately. Checking the unit together with the system saves time and avoids replacing working components. We also ask how the boiler behaves during long water draw-off and when heating is turned on after a long idle period: these modes most often reveal a hidden defect that doesn't show up in a short start-up. You can pay via Kaspi QR, Kaspi Red, card, cash or bank transfer, and the warranty is 1 year on labor and parts.
While the technician is on the way, the owner can do some checks, but some actions will only make the breakdown worse. Below is a list of safe steps and operations best left to a specialist.
Before the technician arrives, it's safe for the owner to check the pressure on the gauge, the power supply, the position of the valves and write down the error code. Look at the gauge needle: in wall-mounted models, operating pressure usually stays within 1–2 bar, and a drop below normal immediately explains why the burner goes out during heating. Make sure the unit is connected to power, the automation isn't switched off by the toggle on the panel, the gas valve in front of the unit is open, and the heating and water supply valves are in the operating position — sometimes the cause is a single closed valve after routine maintenance. Write down the code from the display and note what actions caused it: ignition, hot water draw-off or heating to the set temperature. The recorded code and the sequence that triggered it help the technician during diagnostics — such a record helps find the cause faster than a single description of 'not working'.
You shouldn't take apart gas fittings, disable safety automation, or pressurize the gas section without a technician. The gas valve, pressure switch, and draft sensor are components where a mistake during disassembly can lead to a leak or a flashback during ignition, so you shouldn't open them yourself even if the error code on the display is clear. Don't try to jumper the automation contacts or remove it from the safety circuit to "hold out" until a specialist arrives. The pressure switch monitors draft in the flue, and forcibly disabling it removes the backdraft protection—combustion products start flowing into the room instead of outside. Safety automation blocks the boiler for a reason: bypassing it removes protection against gas leaks and backdraft, and that's a risk to people in the house, not a way to save time. If you smell gas, don't turn on lights or touch electrical appliances—close the shutoff valve at the inlet, open a window, and call the gas service.
We explain which Kiturami components fail most often, how we select parts, and what the warranty covers after the repair.
| Component | What happens to it | Repair or replacement |
|---|---|---|
| Heat exchanger | Scale, cracks, fistula from overheating | Install a new one, less often flushing |
| Three-way valve | Stem jams, switching is lost | Component repair or replacement |
| Control board | Relays and traces burn out from surges | Board restoration by soldering |
| NTC sensors | Reading drift, open circuit | Install a new sensor |
| Gas fittings | Clogged nozzles, worn seals | Cleaning, replacement of elements |
| Circulation pump | Bearing wear, rotor sticking | Repair or install a new one |
We select a part by the marking on the component itself and by the boiler model, not by visual similarity. We check the marking against the passport of the specific series—wall-mounted and floor-standing Kiturami units differ even with a similar housing. NTC sensors and gas fitting elements of one revision are visually indistinguishable from another, but they produce different characteristics during operation. That's why the technician first checks the component number against the series passport and then selects the right one: this way we avoid installing a part that formally fits but doesn't maintain the burner mode. A selection error brings back the same breakdown—externally identical valves of different revisions give different characteristics, and the boiler goes into error again. We take parts for a specific component, not "on trial".
Our 1-year warranty covers both labor and parts, and a technician arrives within 60 minutes anywhere in the city. Diagnostics are free, and you can pay with Kaspi QR, Kaspi Red, card, cash, or bank transfer. The warranty is valid only when the cause and the replaced component are recorded in the diagnostics, so we don't replace a part "on trial": without a confirmed cause, a new part doesn't fix the breakdown, and a month later the owner returns with the same code on the display. Therefore, before replacement, the technician records the initial parameters of the component and the result after installation—this shows what exactly changed after the repair. The technician comes to your home or we perform the repair at the service center—Tech Service works as a direct contractor, without intermediaries between the request and the repair.
We've gathered the essentials for Kiturami owners: how to read boiler signals, what to watch for, and why preventive maintenance costs less than emergency repairs.
20brands
Service by brand, with dedicated pages for each. Choose yours.
Tech Service technicians repair other appliances too — with the same 1-year warranty on labour and parts.
Refrigerator Repair in Almatyfrom 3 000 ₸
Washing Machine Repair in Almatyfrom 3 000 ₸
Dishwasher Repair in Almatyfrom 3 500 ₸
Oven Repair in Almatyfrom 3 000 ₸
Cooktop Repair in Almatyfrom 3 500 ₸
Air Conditioner Repair in Almatyfrom 3 500 ₸
Boiler and Water Heater Repair in Almatyfrom 2 500 ₸
Freezer Repair in Almatyfrom 6 000 ₸
Tumble Dryer Repair in Almatyfrom 5 000 ₸
Coffee Machine Repair in Almatyfrom 2 500 ₸
Robot Vacuum Cleaner Repair in Almatyfrom 3 500 ₸
Vacuum Cleaner Repair in Almatyfrom 1 500 ₸
Microwave Oven Repair in Almatyfrom 2 000 ₸
Hair Dryer Repair in Almatyfrom 1 500 ₸
Iron Repair in Almatyfrom 3 000 ₸
Electric Kettle Repair in Almatyfrom 2 500 ₸
Mixer Repair in Almatyfrom 2 500 ₸
Multicooker Repair in Almatyfrom 500 ₸