Open until 19:00+7 (778) 021 13 16Call a technician
Tech Service technician next to a ups and voltage stabilizer

UPS and Voltage Stabilizer Repair in Almaty

A technician arrives within 60 minutes anywhere in the city. Diagnostics are free.

  • 1-year warranty on labor and parts
  • 4 to 20 years of experience

Our own technicians4 to 20 years of experience

Maksim S.Dmitriy R.Rais M.Roman M.

Repair prices

  • Diagnostics0 ₸
  • Battery replacementfrom6 000 ₸
  • Fan replacementfrom7 000 ₸
  • Battery calibrationfrom7 000 ₸
  • Dust cleaningfrom7 000 ₸
All prices
2ГИСЯours4,97 898 reviews
2GIS · Google · Yandex · order database
Common faultsCommon faultsTECH SERVICE02

Common UPS faults in Almaty

Below are common symptoms and their likely causes. The technician names the exact cause after free diagnostics.

PricesPricesTECH SERVICE03

How much UPS repair costs in Almaty

The table lists the 'from' price for labor, for common jobs also the 'from' price of the part, plus the time required to complete the job.

Battery replacementparts not included

1–2 hours

from6 000 ₸

Fan replacementparts not included

1–2 hours

from7 000 ₸

Battery calibrationexact price — after the free diagnostics

1–2 hours

from7 000 ₸

Dust cleaningexact price — after the free diagnostics

1–2 hours

from7 000 ₸

Charging circuit repairparts not included

1–3 hours

from8 000 ₸

Before and afterBefore and afterTECH SERVICE04

Before and after UPS repair in Almaty

Worn-out batteries

1 visittime

from 7 000 ₸cost

Problem
The UPS stopped holding the load: when the mains failed, the device shut off immediately, the battery compartment housing was swollen, and white acid traces and corrosion were visible on the terminals.
What we did
The technician checked the batteries, confirmed the wear, and replaced the batteries with new sealed ones, cleaned the terminals and installed fresh connectors, and removed the acid traces.
Result
The UPS holds the load again when the mains fails, the batteries sit level, and the terminals are clean. 1-year warranty on labor and parts.
I want the same
UPS: worn-out batteries — after repairBeforeAfter
01 / 03
All repairs
TECH SERVICE mobile technician with a tool case

How UPS repair works at your home or office in Almaty

Five steps from request to final check, with free diagnostics and a warranty.

  1. Requestphone/web

    Describe the symptom and the device model so the technician understands the likely cause in advance.

  2. Technician visitin 60 min

    The technician arrives anywhere in the city within 60 minutes of your request.

  3. Diagnosticsfree

    The technician checks the battery, voltage and switchover to battery, then names the cause of the fault.

  4. Approval of workafter check

    You approve the scope of work and the cost, and then the technician starts the repair.

  5. Check after assemblyafter repair

    The technician shows the device working; when you accept it, check power-on, switchover to battery and the indicators.

Leave a request
TechniciansTechniciansTECH SERVICE05

Our computer and laptop repair technicians in Almaty

The computer and laptop repair department in Almaty has 7 technicians with 6 to 15 years of experience.

  • 7 technicians in Almaty
  • 6–15 years of experience in the department
  • Article author Maksim S., 10 years of experience
Mobile technician fixing a washing machine at the customer's home
Field technician at a customer’s home

The department has 7 specializations — they are listed on the technicians' cards.

01 / 07
Maksim S., graphics card repair technicianexperience10 years

Maksim S.

Graphics card repair technician

Dmitriy R., PC and laptop diagnostics technicianexperience6 years

Dmitriy R.

PC and laptop diagnostics technician

Rais M., laptop repair engineerexperience8 years

Rais M.

Laptop repair engineer

Roman M., software installation specialistexperience10 years

Roman M.

Software installation specialist

Sergey A., PC and laptop repair technicianexperience7 years

Sergey A.

PC and laptop repair technician

Sergey M., diagnostics and virus removal specialistexperience13 years

Sergey M.

Diagnostics and virus removal specialist

Turarbek K., consultantexperience15 years

Turarbek K.

Consultant

We reply during working hours

Book UPS repair in Almaty

Leave a request and a technician will arrive within 60 minutes anywhere in the city. Diagnostics are free. 1-year warranty on labor and parts. You can pay via Kaspi QR, Kaspi Red, bank card, cash, or bank transfer for companies.

TECH SERVICE administrator replying to a customer's WhatsApp message

Warranty question? Call us

+7 (778) 021 13 16
Customer reviewsReviewsTECH SERVICE06

Reviews of UPS repair in Almaty

Ерасыл Б.Order No. ZK-2026/516 · 20 October 2026

ours

Работаю допоздна, поэтому нужен был сервис с нормальным графиком. Основная жалоба — не стабилизирует. Шум пропал, работает мягко

Repair: ups and voltage stabilizer repair in

Елена К.Order No. 63288 · 15 October 2026

ours

Жалоба простая: не стабилизирует. Дамир М подсказал, как продлить жизнь технике. Проверили на всех режимах, всё чётко.

Repair: ups and voltage stabilizer repair in

Жасмин Р.Order No. TS-6130 · 13 December 2025

ours

Было важно, чтобы сделали до выходных — гости, то-сё. Сначала просто глючило, потом стало хуже: не стабилизирует. Рустем Т взялся за то, от чего другие отказались. Могли бы взять больше, но взяли по-божески. Пользуюсь ежедневно, вопросов нет.

Repair: ups and voltage stabilizer repair in

Тимур А.Order No. 69595 · 2 December 2025

ours

Долго откладывал ремонт, потом всё-таки собрался. Основная жалоба — не включается. Позвонил в techservice по объявлению, всё совпало. Вернули в тот же день, всё функционирует.

Repair: ups and voltage stabilizer repair in

Аяна Е.Order No. TS-2509-510 · 20 November 2025

ours

Рустем Т помог выбрать, без навязывания. С тех пор ни разу не подвёл. Вернули в тот же день, всё функционирует.

Repair: ups and voltage stabilizer repair in

Молдир С.Order No. 18427 · 25 July 2025

ours

Жалоба простая: пищит. Сергей Архипов честно сказал, что менять, а что ещё походит. Сказать, что доволен — ничего не сказать

Repair: ups and voltage stabilizer repair in

Гульнара Б.Order No. ZK-3514 · 30 March 2025

ours

Ремонт стабилизатора напряжения — вот с этим и пришёл. С чем пришёл: выключаеться. Всё оформили по договору, с печатью. Могли бы взять больше, но взяли по-божески. Деталь на замену — плата. Пришлось самому напоминать про гарантийный талон. Сделали и забыл про проблему.

Repair: ups and voltage stabilizer repair in

Бекзат Т.Order No. 68147 · 9 September 2024

ours

С чем пришёл: пищит. Сергей Архипов возился с этим дольше, чем планировал, но довёл до конца. Ребята из techservice работают давно, это чувствуется. Уже полгода — ни одного сбоя.

Repair: ups and voltage stabilizer repair in

Марат Ж.Order No. 36834 · 12 March 2024

ours

Работаю допоздна, поэтому нужен был сервис с нормальным графиком. Больше всего напрягало: не включается. Роман Мигунов возился с этим дольше, чем планировал, но довёл до конца. Проверили при мне, показали, что всё держит.

Repair: ups and voltage stabilizer repair in

Андрей П.Order No. TS-2406-394 · 28 February 2024

ours

Основная жалоба — выключается. Рустем Т приехал в тот же день, хотя был конец смены. Проверил дома — всё на месте, ничего не забыли.

Repair: ups and voltage stabilizer repair in
Questions and answersQuestionsTECH SERVICE07

Questions about UPS repair in Almaty

Didn’t find the answer? Message us on WhatsApp.

Ask a question
Why does the UPS beep every few seconds even though the power hasn't gone out?

That beeping usually means the UPS is running on battery or the battery is low: check if there's voltage at the outlet and whether the output is overloaded. If the power supply is fine, the cause is more often the battery or the charging circuit — it depends on the model.

The UPS is connected to power, but when the electricity goes out, the computer shuts down immediately — is it the battery or the board?

Most often it's the battery: it has lost capacity and can't handle the load. Less often the problem is in the charging circuit or the inverter — a technician will check both during free diagnostics and tell you for sure.

Can I install a higher-capacity battery in the UPS?

Yes, often you can if the voltage and dimensions match, but the runtime won't always increase proportionally. Keep in mind that the charger may not be designed for a larger capacity — check with your model.

Do you repair voltage stabilizers on-site in Almaty?

For powerful relay and servo models, the technician often services them on-site, while compact ones are easier to bring to the service center. A call-out within the city takes about 60 minutes, and diagnostics are free.

Will repairing the UPS for a gas boiler help keep the heating on during power outages again?

Yes, if the cause is the battery or the charging circuit, after repair the UPS will again power the boiler when the power goes out. If the inverter is faulty, the technician will assess what's more cost-effective — repairing the unit or replacing the device.

What should I do with a UPS that hums and heats up before the technician arrives?

Unplug it from the power and the load, don't take it apart or turn it back on. Humming and heating may indicate a problem with the fan, transformer, or board — the technician will check on-site.

Repair guideArticleTECH SERVICE08

UPS and voltage stabilizer repair in Almaty by Tech Service technicians

Maksim S., graphics card repair technician

Author: Maksim S.,Graphics card repair technician

Published
Updated

We repair UPS units and voltage stabilizers in Almaty with our own technicians: standby, line-interactive and online power supplies, as well as relay, servo and inverter stabilizers. A technician arrives within 60 minutes anywhere in the city, diagnostics are free, and we name the cost after them. We give a 1-year warranty on labor and parts, and our technicians have 4 to 20 years of experience.

Where UPS and voltage stabilizer repair begins

One common name covers devices with different circuits. The circuit decides which component wears out first, so the technician identifies the type of power supply before looking for the fault.

Standby, line-interactive and online UPS

A standby UPS passes mains voltage straight through in normal mode and starts its inverter only when the power goes out. A line-interactive model adds a multi-tap autotransformer to this circuit: when voltage sags or rises, a relay switches the winding, and your equipment gets corrected power without switching to battery. An online double-conversion unit works differently, constantly rectifying the incoming current and rebuilding the sine wave with its inverter, so a computer, server or boiler never notices fluctuations at all. Each circuit has its own weak spot. Standby and line-interactive units suffer from relay and battery wear, while an online unit runs a constant load on its power switches and fan. That is why cooling deserves attention first on an online model: a dust-clogged grille is the fastest route to overheating and an emergency shutdown.

Device type, weak component and what we check

Device typeWeak componentWhat we check first
Standby UPSBattery, transfer relayRuntime and switchover to battery
Line-interactive UPSTap relays, AVR boardOutput voltage during a sag
Online UPSPower switches, fanHeating, sine wave shape
Relay stabilizerRelay contactsClicking, burnt contacts
Servo stabilizerBrush, drive motorBrush travel along the winding
Electronic stabilizerTriacs, control boardShorted switches, board signals
Inverter stabilizerCapacitors, transistorsRipple, overheating protection

Relay, servo and inverter stabilizers

Voltage stabilizers fail in different ways: a relay unit burns its relay contacts, a servo unit wears down its carbon brush and tires its drive motor, and electronic and inverter units short their power switches and dry out their capacitors. A relay model switches autotransformer taps in steps, so every fluctuation in the mains comes with a click, and years of switching gradually destroy the contacts. A servo drive moves the brush smoothly along an open winding, but dust and sparking leave deposits on the track. Electronic circuits run silently, so their faults appear suddenly, and the device simply stops turning on. We start UPS and voltage stabilizer repair in Almaty by asking how the equipment behaved before it failed. When you call, tell the technician whether the lights flickered, whether you heard clicking and whether you smelled burning: these details reveal the type of fault before the case is even opened.

The battery as the main reason a UPS fails

The battery is the consumable part of any uninterruptible power supply. We explain how to spot its wear, how to tell it apart from an electronics fault and which parameters guide the choice of a replacement.

Signs that the battery has reached the end of its life

  • Short runtime: when the power goes out, the computer lasts only a few seconds instead of the minutes it used to, then shuts down along with the monitor.
  • Replacement indicator: a battery icon lights up on the panel, and the monitoring software reports that the battery module needs replacing.
  • Frequent beeping: the unit beeps at every small fluctuation because a weak battery cannot handle even a brief switchover.
  • Warm case: the back panel is noticeably warmer than usual under the same load, as the charging circuit keeps trying to top up the cells.
  • Deformation: swollen battery walls, leaks and white deposits on the terminals are a reason to unplug the device from the socket at once.

Battery or charging circuit

We tell battery wear apart from a charging circuit fault with two measurements: the terminal voltage after several hours of charging and how far it drops under load. A healthy sealed lead-acid AGM battery shows slightly above its rated voltage after charging and drops smoothly under load. A worn one holds normal voltage with no load but collapses almost as soon as the inverter starts working. If the terminal voltage stays low even after a full day plugged in, the problem lies in the charging circuit: a shorted diode, a dried-out capacitor or a faulty charge current regulator. That is why our UPS diagnostics always cover both parts, not only the battery. In our view, this is the key lesson for owners: if a new battery stops holding the load again within a week, replacing it once more is pointless, and the charger must be repaired first.

How we choose a replacement battery

We choose a new battery by four parameters of the old one: rated voltage, capacity in amp-hours, dimensions and terminal type. Home units for a computer use one or two small cells, while models for boilers and office equipment use packs of several batteries connected in series. In a pack, all cells are replaced at once: a fresh battery next to old ones quickly levels down to their condition and loses its service life. The technician also checks the mounting and connectors so the new battery fits without modifying the case. Our technicians, with 4 to 20 years of experience, also pay attention to the charging current of the unit. A battery with much larger capacity than the manufacturer intended charges longer and heats the charging circuit more, so such a choice is better discussed in advance rather than made just for a few extra minutes of runtime.

What beeping, clicking and humming mean

Sounds and indicators are the first clue to a fault. The type of signal shows whether to look for the cause in the battery, the load, a relay or the electronics, and where the technician should start checking.

UPS signals and their likely cause

What you hear and seeLikely causeWhat the owner should do
Occasional beep with power onMains fluctuations, running on batteryCheck the socket voltage
Continuous alarmOutput overloadUnplug extra devices
Frequent beeping, battery icon flashingDischarged batteryLet it charge, then check
Beeping right after power-onFaulty battery, internal errorNote the code, call a technician
Error code on the displayBoard fault, overheatingTake a photo of the display
Clicking without a power cutAVR tap relays at workWatch how often it repeats

The stabilizer clicks and the lights flicker

Frequent clicking together with flickering lights means the stabilizer relay switches taps too often or its contacts have burnt and no longer carry the current. In normal operation, a relay model clicks rarely, only on noticeable mains fluctuations. If the clicks come in bursts and the lamps dim in time with them, we check the control board, the input voltage sensor and the relay contacts themselves. The opposite also happens: the mains really is unstable, the stabilizer works fine, but it was chosen without enough range margin. A steady transformer hum under load is normal, whereas crackling, buzzing with case vibration and a smell of hot varnish point to an overheated winding. A Tech Service technician works out which scenario you have and explains it after free diagnostics. A practical tip: do not run a refrigerator and a powerful heater on one stabilizer, because frequent compressor starts at the power limit speed up relay wear.

The UPS does not switch to battery during a power cut

If the computer shuts down at the same moment as the lights, one of three components is to blame: a worn battery, the transfer relay or the inverter, which should start within a fraction of a second. We check them in order. First, we test the battery under load, since it is the most common cause. Then we simulate a power cut and listen for the relay: if it clicks but the output stays dead, the inverter is not starting or its power transistors are shorted. No click points to the relay itself or the control board. Sometimes the cause is simpler: the equipment is plugged into surge-only outlets without battery backup, which many models have. You can test the switchover at home yourself: save your work, close important files and pull the UPS plug from the wall; if the computer turns off, you need a technician.

How UPS and voltage stabilizer repair works with us

The procedure is the same for UPS units and stabilizers: a request, the technician visit, a free check, approval of the work and a final test under the real load of the owner.

Technician visit or work at the service center

Our technician arrives within 60 minutes anywhere in the city, and home UPS units and stabilizers can often be fixed on the spot. Tech Service is a direct provider: the specialist who comes to you does the check and the repair personally, with no middlemen and no reselling of your request. On site, the technician replaces batteries, cleans dust out of the device, checks sockets and wiring and finds a blown fuse. If the fault needs board soldering, replacement of power transistors or rewinding, the device is taken to the service center. You do not need to carry a heavy floor-standing stabilizer weighing dozens of kilograms yourself: it is inspected where it stands first, and only then is a decision made about service center work. Describe the model and power rating of your equipment when you call, so the technician knows what to expect and brings the right tools.

What free diagnostics include

  • Visual inspection: we check the case, ventilation grilles, battery terminals and connectors for signs of overheating, swelling and electrolyte leaks.
  • Voltage measurements: we measure the input and output of the device to see whether the home wiring is sound and how regulation works.
  • Battery test: we test the battery under load and tell cell wear apart from a faulty charging circuit.
  • Power cut simulation: we cut the mains and check how quickly the relay trips and the inverter starts with your equipment connected.
  • Result for the owner: UPS diagnostics and repair are agreed separately: first the technician names the cause and the cost, and work starts only with your approval.

Warranty, payment and the check after repair

We give a 1-year warranty on labor and parts, covering both battery replacement and component-level board repair. You can pay in any convenient way, as we accept Kaspi QR, Kaspi Red, bank card, cash, or bank transfer for companies. The technician names the cost after free diagnostics, once it is clear which component has failed and what the repair requires. After the repair, the device is tested not at idle but with the equipment it was bought for: a computer, router, boiler or refrigerator. The technician simulates a power cut again and checks the runtime and how warm the case gets after several minutes of operation. For a stabilizer, the output voltage is monitored while powerful appliances are switched on. This check matters because some faults appear only under load, so a test with real equipment shows the repair result more honestly than any measurement without it.

What to do before the technician arrives

A few simple steps protect the equipment from further damage and the owner from electric shock and burns. We have gathered the danger signs, common mistakes and what to prepare for the visit.

When to unplug the device at once

  • Burning smell: a smell of hot plastic or varnish means an overheated winding or board, so pull the plug and do not switch it on again.
  • Swollen battery: bulging battery walls and leaks risk an electrolyte spill, and such a battery should never be touched with bare hands.
  • Smoke and sparks: any sparks from the grille signal a breakdown, so cut the power at the breaker panel rather than by grabbing the case.
  • Strong heat: a case too hot to keep your palm on points to a failed fan or an overloaded output.
  • Crackling inside: dry crackling and irregular clicks indicate insulation breakdown, and further operation is dangerous for the connected equipment.

What not to do yourself

Do not fit a higher-rated fuse or open the case yourself, even if the device was unplugged long ago. The inverter and input filter capacitors keep their charge after disconnection, and touching their leads is dangerous. A fuse does not blow by chance: usually the varistors that absorbed a voltage surge fail before it, or the power switches short out. A jumper in its place removes the protection, and the next power-on burns out the board. After a thunderstorm or a substation failure, do not switch the device on several times in a row hoping it will start, because each attempt adds damage. Do not bypass the unit by connecting equipment straight to its output through a multi-socket extension cord. It is better to move the computer to a regular socket and wait for the check than to risk both the computer and the power supply.

What to prepare for the visit

Before the specialist arrives, write down the model and power rating from the label on the case and describe what happened before the failure. Take a photo of the error code on the display, if there was one, and note the sounds: occasional beeps, a continuous alarm, clicking or humming. We need to know what is connected to the output, such as a computer, router, heating pump or boiler, because the load determines which checks come first. Clear access to the socket and to the device itself: a floor-standing stabilizer behind a wardrobe is hard for the technician to inspect. We name the UPS repair price after free diagnostics, once the cause is confirmed, not from a description over the phone. The more precisely you describe the symptoms, the faster the technician tells a discharged battery from a board fault without wasting time on extra measurements.

Load and care after repair

Repeat failures are more often caused by overload and dust than by the quality of parts. We explain what you can connect to a power supply and how to extend its service life.

Which equipment you can connect to a UPS

EquipmentCan it be connectedWhy
Computer and monitorYesThe UPS was designed for them
Router, modem, video camerasYesLow power, long runtime
Gas boiler and pumpYes, with a sine waveBoiler controls are sensitive to waveform
Laser printerNoFuser inrush current overloads the inverter
Heater, kettle, ironNoPower exceeds what a home model handles
RefrigeratorOnly an online model with marginCompressor inrush current

A UPS for a gas boiler and pump

A power supply for a gas boiler must keep the controls and the circulation pump running, so a pure sine wave at the output matters. Standby models with a simulated sine wave produce a stepped signal, and the boiler electronics may treat it as a fault, show an error and shut off the burner. If the boiler stops working during a power cut, we check three things: the output waveform, the condition of the batteries and correct phase and neutral wiring, which many boilers are sensitive to. External batteries of such a unit usually sit in a separate compartment, and their connections oxidize too. As a UPS repair service center, we look at the whole system, not only the unit itself. Check the runtime before the heating season and the first cold spell: without a working UPS, even a short winter power outage cools the house quickly.

How to extend the service life of the device

The service life of a UPS and a stabilizer depends on three conditions: room temperature, the amount of dust and how deeply the battery is discharged. A lead-acid battery loses capacity faster in heat, so the device should not stand next to a radiator, on a sunny windowsill or in a closed cabinet without ventilation. Dust clogs the grilles and fan blades, the temperature inside the case rises, and capacitor wear speeds up with it. Deep discharges down to full shutdown also shorten battery life, so during a long outage it is better to turn the computer off right away without waiting for the low-battery alarm. On every visit, our technicians show owners where the ventilation openings are on their model and how to clean them. Every few months, run a simple test: pull the plug with the equipment on and time how long the battery lasts, so wear shows up before it lets you down at an important moment.

UPS repair explained

An uninterruptible power supply and a stabilizer last a long time if the first signs of wear are noticed in time. Here are the essentials to help owners protect their equipment and not miss a fault.

  • Circuit type: standby, line-interactive and online units, like stabilizers of different designs, fail in different ways, so any check starts by identifying the circuit.
  • Battery: short runtime and frequent beeping are usually linked to the battery, but if a new battery drains quickly, the charging circuit is at fault.
  • Sounds: occasional beeps, a continuous alarm, bursts of clicks and crackling point to different components and are worth noting before the specialist visits.
  • Safety: with a burning smell, a swollen battery, smoke or strong heat, the device is disconnected at once and the case is never opened at home.
  • Load: a laser printer, heater and kettle are not connected to a home UPS, and a boiler needs a model with a pure sine wave.

21brands

Which UPS brands we repair in Almaty

We repair UPS units and voltage stabilizers from common brands — find yours in the list.

We also repairWe also repairTECH SERVICE09

Besides UPS repair, we fix other equipment in Almaty

Tech Service technicians repair other appliances too — with the same 1-year warranty on labour and parts.

BlogBlogTECH SERVICE10

Worth reading before UPS repair in Almaty

Leave a review

Choose a platform — the TECH SERVICE page will open.

2ГИС2GISGoogle MapsЯYandex Maps
Send a review with photos on WhatsApp