Open until 19:00+7 (775) 030 02 94Call a technician
Tech Service technician next to a gas boiler

Hubert Gas Boiler Repair in Almaty

A technician arrives within 60 minutes anywhere in the city. Free diagnostics.

  • 1-year warranty on labor and parts
  • 4 to 20 years of experience

Our own technicians4 to 20 years of experience

Ruslan Ts.Damir M.Dilmurat S.Dima

Repair prices

  • Diagnostics0 ₸
  • Fan replacementfrom5 500 ₸
  • Temperature sensor replacementfrom6 000 ₸
  • Control board replacementfrom6 000 ₸
  • Gas valve replacementfrom7 000 ₸
All prices
2ГИСЯours4,97 898 reviews
2GIS · Google · Yandex · order database
Common faultsCommon faultsTECH SERVICE02

Common Hubert gas boiler faults in Almaty

Below are safe steps that don't require opening the boiler. They help clarify the symptom but don't replace diagnostics.

PricesPricesTECH SERVICE03

How much Hubert gas boiler repair costs in Almaty

The table lists the 'from' price for labor, for common jobs also the 'from' price of the part, plus the time required to complete the job.

Fan replacementparts not included

1–2 hours

from5 500 ₸

Temperature sensor replacementparts not included

1–2 hours

from6 000 ₸

Control board replacementparts not included

1–2 days

from6 000 ₸

Gas valve replacementparts not included

1–2 hours

from7 000 ₸

Three-way valve repairparts not included

1–2 hours

from7 500 ₸

Before and afterBefore and afterTECH SERVICE04

Before and after Hubert gas boiler repair in Almaty

Hot water barely warm, radiators heating

1 visittime

from 7 500 ₸cost

Problem
For a Hubert gas boiler, hot water from the tap came out barely warm, while the radiators were heating.
What we did
The technician opened the lower compartment of the boiler and found that the servo drive of the three-way valve was not switching the stuck stem; he replaced the servo drive, worked the stem loose, and checked the switching.
Result
Hot water is hot again, the radiators heat as usual; the technician checked the switching of the three-way valve.
I want the same
Baxi gas boiler: hot water barely warm, radiators heating — after repairBeforeAfter
01 / 04
All repairs
TECH SERVICE mobile technician with a tool case

How Hubert gas boiler repair works at your home in Almaty

From request to performance check — five steps.

  1. Requeston the day of request

    Describe the symptom; the technician will clarify details and arrange a visit.

  2. Technician visitas agreed

    The technician brings tools and common parts for the Hubert model and confirms the exact visit time by phone.

  3. Inspection and planbefore repair

    The technician explains the fault found and specifies what work and parts are needed.

  4. Repairupon approval

    Work is performed after the scope and cost are approved.

  5. Approval and reportafter work

    The technician records the completed work and gives the owner the documents at the end of the visit.

Leave a request
TechniciansTechniciansTECH SERVICE05

Our home appliance repair technicians in Almaty

The home appliance repair department in Almaty has 8 technicians with 8 to 12 years of experience.

  • 8 technicians in Almaty
  • 8–12 years of experience in the department
  • Article author Ruslan Ts., 9 years of experience
Technician repairing a gas boiler at a customer’s home
Field technician at a customer’s home

The department has 8 specializations — they are listed on the technicians' cards.

01 / 08
Ruslan Ts., washing machine and refrigerator repair technicianexperience9 years

Ruslan Ts.

Washing machine and refrigerator repair technician

Damir M., general household appliance repair technicianexperience12 years

Damir M.

General household appliance repair technician

Dilmurat S., field technician for washing machine and refrigerator repairexperience10 years

Dilmurat S.

Field technician for washing machine and refrigerator repair

Dima, expert washing machine repair technicianexperience8 years

Dima

Expert washing machine repair technician

Nikita M., field refrigerator repair technicianexperience8 years

Nikita M.

Field refrigerator repair technician

Oraz, senior washing machine repair technicianexperience8 years

Oraz

Senior washing machine repair technician

Radik T., dishwasher repair technicianexperience11 years

Radik T.

Dishwasher repair technician

Rustem T., washing machine repair technicianexperience9 years

Rustem T.

Washing machine repair technician

We reply during working hours

Book Hubert gas boiler repair in Almaty

Describe the Hubert boiler fault by phone — the technician will arrange a visit time and specify the needed parts.

TECH SERVICE administrator replying to a customer's WhatsApp message

Warranty question? Call us

+7 (775) 030 02 94
Customer reviewsReviewsTECH SERVICE06

Reviews of Hubert gas boiler repair in Almaty

Гаухар Н.Order No. TS-2805 · 23 April 2026

ours

Дамир М принял, посмотрел и сразу сказал, что делать. Сказали 9 500, а потом ещё и скидку сделали. Сделали и забыл про проблему.

Repair: gas boiler repair in

Богдан С.Order No. 938445 · 24 March 2026

ours

Друг посоветовал, у него похожая история была. Нужен был ремонт газовой колонки — обратился сюда. Проблема — не зажигается. Поставили новую деталь: мембрана. По цене не скажу, что дёшево, но справедливо. Заявку приняли по телефону, перезвонили через десять минут. Вернули в тот же день, всё функционирует.

Repair: gas boiler repair in

Ольга М.Order No. 2024-2927 · 9 September 2024

ours

Основная жалоба — не греет воду. Никита М помог выбрать, без навязывания. Сказать, что доволен — ничего не сказать

Repair: gas boiler repair in

Ерасыл Б.Order No. TS-2202-231 · 2 April 2022

ours

Симптом был очевидный: не зажигаеться. Никита М приехал в тот же день, хотя был конец смены. Уже полгода — ни одного сбоя.

Repair: gas boiler repair in

Жасмин Р.Order No. 13909 · 18 December 2019

ours

Смотрел, у кого есть запчасти на такую модель. Не люблю сервисы, но этот запомнил. Симптом был очевидный: не зажигается. Отдельно спосибо мастеру — Дамир М, терпения ему хватило. Нужна была замена: теплообменник. Уже полгода — ни одного сбоя.

Repair: gas boiler repair in

Алмас Д.Order No. TS-1908-726 · 14 November 2019

ours

Симптом был очевидный: ошибка. Дамир М помог выбрать, без навязывания. Пользуюсь ежедневно, вопросов нет

Repair: gas boiler repair in

Азамат Е.Order No. TS-1811-750 · 31 July 2018

ours

Позвонил знакомому, он раньше работал в сервисе, посоветовал этих. Обратился по поводу газовой колонки. Больше всего напрягало: течёт. Из деталей — розжиг. Заявку приняли по телефону, перезвонили через десять минут. По деньгам вышло адекватно, в другом месте просили больше. Включил, проверил, работает

Repair: gas boiler repair in

Дмитрий Л.Order No. ZK-5171 · 21 July 2018

ours

Хотел сначала вызвать мастера на дом, потом передумал. Больше всего напрягало: ошибка. Сделали аккуратно, следов разборки не видно.

Repair: gas boiler repair in

Дмитрий Л.Order No. ZK-2017/954 · 2 December 2017

ours

Работаю допоздна, поэтому нужен был сервис с нормальным графиком. Первое, что заметил: не зажигаеться. Пользуюсь ежедневно, вопросов нет.

Repair: gas boiler repair in

Руслан Д.Order No. 2017-6867 · 24 April 2017

ours

Проблема — течёт. Никита М помог выбрать, без навязывания. Проверил дома — всё на месте, ничего не забыли.

Repair: gas boiler repair in
See all reviews
Questions and answersQuestionsTECH SERVICE07

Questions about Hubert gas boiler repair in Almaty

Didn’t find the answer? Message us on WhatsApp.

Ask a question
Where in Almaty can I book a Hubert gas boiler repair with a technician visiting my home?

At Tech Service, you can request a Hubert boiler repair by phone or through the website. A technician arrives at your home within 60 minutes anywhere in the city. Diagnostics are free, and the cost of work is quoted after inspection.

Which gas boiler is best for a private house in Almaty?

Focus on the power output for your home's area, the combustion chamber type, and service availability for the brand. Hubert is a workable option if there are technicians nearby who service this brand.

Why won't a Hubert boiler start after the summer, and what should I check?

After a period of inactivity, a Hubert often fails to start due to air in the gas line or a stuck pump. Close and reopen the gas valve, check the pressure on the gauge, and if it doesn't ignite, call a technician.

The control board on my Hubert burned out—can it be repaired or does it need to be replaced?

Most often, a Hubert control board can be repaired: the technician checks the traces, relays, and contacts and replaces failed components. Replacement is needed for serious damage, and this depends on the boiler model.

My Hubert boiler keeps losing pressure—I add water every week. What's the cause?

Constant pressure loss points to a leak in the heating circuit or a faulty expansion tank. The technician will check the system's tightness and the tank's condition to fix the cause, not just keep adding water.

Can a Hubert gas boiler be repaired on-site, or does it have to be taken to a service center?

Most Hubert gas boiler breakdowns are fixed by the technician on-site, as they carry tools for typical jobs. The boiler is only taken to the service center in complex cases, depending on the model and the nature of the fault.

Repair guideArticleTECH SERVICE08

Hubert Gas Boiler Repair in Almaty by Tech Service Technicians

Author: TECH SERVICE editorial team

Published
Updated

Tech Service repairs Hubert gas boilers in Almaty with its own technicians who have 4 to 20 years of experience. A technician arrives at your home within 60 minutes anywhere in the city, diagnostics are free, and we quote the cost of work after diagnostics. We provide a 1-year warranty on labor and parts and you can pay via Kaspi QR, Kaspi Red (instalments), bank card, cash, or bank transfer for companies.

Hubert Boiler Error Codes and What to Do About Them

When your Hubert boiler shows a code on the display, it's not random — it's the self-diagnostic system pointing to a specific component. Here's how to read that hint, when to reset it, and when to call a technician.

What the Error Code on the Hubert Display Means

The combination on the Hubert screen is the result of the control board's self-diagnostic, which detects a deviation in a specific component and blocks ignition for safety. The electronic control board polls the temperature, pressure, and ionization sensors, compares the readings with the acceptable range, and if they go beyond the limits, stops the burner and displays a digital code. The decoding of Hubert faults is different for each line: the same combination on a model with an atmospheric burner and on a turbocharged version can mean different components. The same code on different Hubert models may point to different components, so always check the decoding against the manual for your specific model, not general tables from the internet. If you need Hubert gas boiler repair in Almaty, the technician starts with the manual and actual sensor readings — that way the cause is found without replacing parts at random.

When You Can Reset the Error Yourself and When You Need a Technician

You can reset the signal with the Reset button if it's a one-time event — for example, after a voltage spike or a brief pressure drop — and the boiler runs normally after reset. In this case, the electronic control board simply recorded a temporary out-of-range parameter and went into protection mode; restarting returns it to operating mode. The pressure sensor often gives false readings during fluctuations in the water supply or when there's an air lock in the circuit — after the pressure stabilizes, the deviation goes away on its own. If the same combination returns after resetting two or three times, it's not an electronics glitch but a real component failure — and further resets only mask the problem. In our practice, a repeating warning almost always means a worn part, not a random fault, so further diagnostics are done by a technician: they check the component itself, not just the picture on the screen.

Ignition Error, Overheating, and "Won't Turn On" — Three Common Scenarios

  • Ignition error: the flame sensor doesn't detect ionization, or the gas valve isn't supplying gas to the burner.
  • Overheating: the primary heat exchanger is clogged with scale, or the circulation pump isn't moving the heat carrier through the circuit.
  • Won't turn on: no power to the electronic control board, or overcurrent protection has tripped.
  • Check order: on a service call, the technician first checks the power supply and ionization sensor — the symptoms are similar, but the work needed is different.
  • Our visit: diagnostics in the city are free, the technician arrives within 60 minutes, and we provide a 1-year warranty on labor and parts.
  • Technician experience: Hubert gas boiler servicing in Almaty is handled by specialists with 4 to 20 years of experience — they can tell a false sensor signal from a real component failure.

Typical Hubert Breakdowns and What Exactly Gets Fixed

Hubert owners usually come with a symptom, not the name of a component. Here's the "symptom → component → repair" chain so you understand what the technician is dealing with.

No Hot Water but Radiators Are Hot — Control Board or Three-Way Valve

If the heating works but the tap water is cold, the three-way valve is usually to blame — it's not switching to the hot water circuit, and the electronic control board is typically fine in this scenario. The mechanism seizes up from scale caused by hard water and stops moving the stem between circuits: heating keeps circulating, but the tap water stays cold. We disassemble the unit, clean the seat and stem, check the actuator travel, and replace the part entirely if worn. We check the electronics just in case for this complaint, but when the radiators are hot and the water is cold, the cause is almost always mechanical. With hard water, the three-way valve seizes gradually, so for the first few weeks the symptom appears intermittently — it's worth checking the unit before hot water fails completely.

Burner Goes Out and Pressure Drops — What to Check

  • Flame sensor: gets dirty and stops seeing the flame, so the boiler shuts down and throws an ignition error.
  • Gas fittings: the valve and coils lose their tightness over time, and the flame won't hold at low output.
  • Coaxial flue: freezes up or gets clogged, draft drops, and the burner goes out in gusts of wind.
  • Expansion tank: when pressure drops slowly, we check the tank membrane and micro-leaks in the circuit, not the pressure switch.

Noise, humming and scale — cleaning and flushing

Humming and noise in Hubert boilers are most often caused by the fan, scale in the heat exchanger, and air in the system, so cleaning and flushing take care of most such complaints. The turbine starts humming over time due to bearing wear and dust on the impeller, while deposits in the primary and secondary heat exchangers cause boiling and a characteristic hum during heating. We flush both heat exchangers, clean the burner and nozzles, check the turbine, and remove air from the circuit. Scale in the primary heat exchanger reduces heat transfer and forces the boiler to run at its limit, so flushing is done not only for noise but also for overheating. Hard water speeds this up, so at the first signs of humming it's better not to delay flushing.

Repair of the Hubert control board and electronics

The control board is the most expensive component in a Hubert boiler and a common reason for the fear that "they'll make you replace the whole boiler." Let's break down which components can actually be repaired and which have to be replaced.

Repair or replace the board — how we decide

Hubert electronics are more often restored than replaced: failed radio components and fuses are fixed on site, and replacement is needed only when the board itself or its firmware is damaged. Our electronics technician tests the traces, checks capacitors, relays, and triacs, and reflashes the controller if necessary. Voltage spikes hit the input circuits first, so the inspection starts with power and protection. Based on the experience of technicians with 4–20 years of practice, restoration costs less than replacing the unit and preserves the boiler's factory settings. The decision is made after diagnostics, not based on the symptom "it won't turn on" — sometimes the problem is in the power supply or a fuse, and the electronics are fine. Before agreeing to a replacement, ask to see the burned component: if it's just a fuse or relay, installing a new unit would be a waste of money.

Why the Hubert board fails

  • Voltage spikes: fluctuations in the city grid burn out input circuits and varistors, especially during line faults.
  • Lightning strike: a thunderstorm induces a pulse through the power grid or gas pipe, and the protection doesn't always react in time.
  • Wear of radio components: capacitors and relays degrade after 5–7 years of operation, causing ignition and modulation failures.
  • Unqualified intervention: attempts to fix the electronics without a schematic and instruments finish off the traces and microchips.

It won't turn on and the display is dark — where we start

If the Hubert display is dark, we first check the power supply and fuse, and then the electronics — that way we rule out simple causes before concluding there's a fault. The technician tests the power cord, terminals, checks the input fuse, and verifies voltage at the connector. The control board receives power through a separate circuit, and a break there produces exactly the same picture as a burned-out controller. Next we look at the indicators and button response: a live unit shows signs of life even when it doesn't start the burner. A dark display doesn't always mean dead electronics: sometimes it's just a bad contact or a fuse, and replacement in that case would be a waste of money. So start with the power supply — it's the fastest way to rule out a false conclusion.

How the technician visit and free diagnostics work

It's important for the owner to understand what happens after a request: who will come, what they'll do on site, and when they'll quote the price. Here's the step-by-step process.

Does the technician come to your home or does the boiler need to be taken to the service center

In Almaty, a Tech Service technician reaches the owner within 60 minutes anywhere in the city, and most Hubert issues are resolved on-site without taking the boiler away. The specialist services both wall-mounted and floor-standing models in the line, including single- and double-circuit versions. On-site, they see the entire heating system — circuit pressure, flue, water quality — so they often find the cause faster than in a workshop. Only some faults require a bench: for example, deep soldering of the control board or testing components under load. In my view, on-site service wins in most cases precisely because of context: the specialist immediately sees how the unit is integrated into the piping and how it behaves under real system pressure. If your case needs a bench, they will tell you after the inspection — that conclusion is not made in advance.

What free diagnostics includes and when the price is quoted

Diagnostics are free: the specialist checks the boiler, identifies the component and cause, then quotes the cost of work — before any actions. The check includes inspecting the burner and combustion chamber, measuring circuit pressure, assessing draft and flue condition, and checking the three-way valve and electronic board for errors. The price is quoted after the inspection because the same symptom can point to different components, and an honest price is only possible after seeing the unit. For example, pressure drop looks the same with a circuit leak and with a faulty expansion tank, but the fix is different in each case. That's why we don't quote over the phone: without an inspection it would be a guess, not a calculation. After the check, you get a specific list of tasks and a decision — fix the component now or monitor it.

How long repair takes and what the technician does on-site

What we doWhat we checkWhat affects the time
Cleaning the burner and nozzlescombustion chamber, carbon buildupdegree of contamination
Flushing the heat exchangerscale, heat transferwater hardness
Replacing the three-way valvecircuit switchingaccess to the component
Repairing the control boardradio components, fusetype of damage
Adjusting modesboiler operating parametersHubert model

Warranty and why it matters that the technician knows the brand

For a Hubert owner, not only the repair itself matters but the result afterward. Here's what warranty we provide and how to tell a brand specialist from a generalist.

What warranty covers repair and parts

We provide a 1-year warranty on labor and parts — the same term for both the repair of the component and the installed part. This covers the control board, three-way valve, sensors, and other elements we replace or restore on Hubert boilers. The year covers both the fact that the work was done and how the new part performs in the heating system. We don't split the warranty into 'short for labor' and 'long for parts' — it's simpler for the owner: if the equipment fails again during this period, we take care of it. A 1-year warranty only makes sense when the technician fixes the cause, not the symptom, so we restore the unit as a whole rather than masking the error. In my view, this principle is what separates a proper repair from a temporary patch before the heating season.

How to tell that a technician really knows Hubert

  • Model before the visit: the technician asks for the exact model and series of the boiler in advance, rather than figuring it out on site by taking the unit apart at random.
  • Typical components: a brand specialist immediately names the weak points of Hubert — the three-way valve, the electronic control board, the flame sensor.
  • Error logic: they explain why the code appeared and what fault lies behind it, instead of just suggesting a part replacement based on symptoms.
  • Brand experience: our technicians have 4 to 20 years of experience — over that time they have seen different generations of Hubert and know where the weak spots are and where a related part is causing the failure.

Repair of a discontinued Hubert model

We still take on repairs of discontinued Hubert models: some components can be repaired, and after diagnostics the technician will tell you which options are realistic for the parts. Being out of production does not mean the boiler is doomed — more often the question is not about a new spare part but whether the mechanism itself can be restored. The control board, valve, and sensors can often be brought back to work without a full replacement, and testing shows where this is possible and where a different approach is needed. For discontinued models, what matters more is not the availability of a new part but the ability to repair the failed component — so diagnostics here decide more than the warehouse. In our practice, owners of such boilers often expect the worst, even though the unit is still quite repairable — it is worth showing it to a technician first rather than looking to replace all the equipment.

Hubert gas boiler service key insights

Breaking down codes, typical failures, and repair procedures comes down to a few practical takeaways that help a Hubert owner make the right decision and not delay contacting us.

  • Self-diagnostics instead of guesswork: the display shows a specific component, not a random failure, so note the code before resetting.
  • Hot radiators with cold water: this scenario more often points to the three-way valve than to the control electronics.
  • Control module: it is usually restored, and replacement is considered only if the board itself is damaged.
  • Free diagnostics at home: identifies the cause and the cost of work before it starts, and the decision remains with the owner.
  • 1-year warranty on labor and parts: applies when the cause is fixed, not just the symptom.

20brands

Besides Hubert, we repair other gas boiler brands in Almaty

We service wall-mounted boilers from various manufacturers. Choose a brand to go to its page.

We also repairWe also repairTECH SERVICE09

Besides Hubert gas boiler repair, we fix other equipment in Almaty

Tech Service technicians repair other appliances too — with the same 1-year warranty on labour and parts.

BlogBlogTECH SERVICE10

Worth reading before Hubert gas boiler repair in Almaty

Leave a review

Choose a platform — the TECH SERVICE page will open.

2ГИС2GISGoogle MapsЯYandex Maps
Send a review with photos on WhatsApp