Open until 19:00+7 (778) 746 00 26Call a technician
Tech Service technician next to a refrigerator

Display Refrigerator Repair in Almaty

A technician arrives within 60 minutes anywhere in the city. Diagnostics are free, plus a 1-year warranty on labor and parts.

  • 1-year warranty
  • Experience from 4 to 20 years
  • Kaspi QR, Kaspi Red, card, cash, or bank transfer

Our own technicians4 to 20 years of experience

Ruslan Ts.Dilmurat S.Nikita M.Damir M.

Repair prices

  • Diagnostics0 ₸
  • Drain line cleaningfrom3 000 ₸
  • Filter drier replacementfrom4 000 ₸
  • Condenser cleaningfrom5 500 ₸
  • Start relay replacementfrom5 500 ₸
All prices
2ГИСЯours4,97 898 reviews
2GIS · Google · Yandex · order database
Common faultsCommon faultsTECH SERVICE02

Common display refrigerator faults in Almaty

Common display refrigerator faults and their likely causes. The technician confirms the exact cause after diagnostics.

PricesPricesTECH SERVICE03

How much display refrigerator repair costs in Almaty

The table shows how much display refrigerator repair costs in Almaty: a starting labor price without parts and the timeline; the technician confirms the total before any work begins.

Drain line cleaninglabour only

1–2 hours

from3 000 ₸

Filter drier replacementrefrigerant not included

1–2 hours

from4 000 ₸

Condenser cleaninglabour only

1–2 hours

from5 500 ₸

Start relay replacementparts not included

1–2 hours

from5 500 ₸

Defrost timer / sensor replacementparts not included

1–2 hours

from6 000 ₸

Before and afterBefore and afterTECH SERVICE04

Before and after display refrigerator repair in Almaty

Door misalignment and poor seal

1 visittime

from 6 500 ₸cost

Problem
The display refrigerator door was misaligned and would not close completely: the gasket did not seal, and frost appeared in the chamber.
What we did
The technician tightened and adjusted the hinges, aligned the door with the cabinet, and checked the gasket seal.
Result
The door closes tightly, the gasket seals around the entire perimeter, and frost no longer appears in the chamber.
I want the same
Two-compartment refrigerator in a kitchen with doors open, a technician in an orange shirt crouched down tightening the middle door hinge with a screwdriverBeforeAfter
01 / 05
All repairs
TECH SERVICE mobile technician with a tool case

How display refrigerator repair works at your home in Almaty

From your request to checking how the display unit works. Diagnostics are free.

  1. Requestcall/website

    Leave a request and describe the symptoms. The technician agrees on a visit time.

  2. Technician visitwithin 60 minutes

    Tell us the display unit model and symptoms so the technician understands the job in advance.

  3. Agreeing on the workbefore repair

    The technician confirms the model and scope of work, then agrees on parts and cost with you.

  4. Repairby complexity

    Work starts once it is agreed. Parts are replaced to match the display unit model.

  5. Accepting the workafter repair

    After the repair, check the cooling and operation of the display unit and look over the serviced components.

Leave a request
TechniciansTechniciansTECH SERVICE05

Our display refrigerator repair technicians in Almaty

The home appliance repair department in Almaty has 8 technicians with 8 to 12 years of experience.

  • 8 technicians in Almaty
  • 8–12 years of experience in the department
  • Article author Ruslan Ts., 9 years of experience
Technician repairing a refrigerator at a customer’s home
Field technician at a customer’s home

The department has 8 specializations — they are listed on the technicians' cards.

01 / 05
Ruslan Ts., washing machine and refrigerator repair technicianexperience9 years

Ruslan Ts.

Washing machine and refrigerator repair technician

Dilmurat S., field technician for washing machine and refrigerator repairexperience10 years

Dilmurat S.

Field technician for washing machine and refrigerator repair

Nikita M., field refrigerator repair technicianexperience8 years

Nikita M.

Field refrigerator repair technician

Damir M., general household appliance repair technicianexperience12 years

Damir M.

General household appliance repair technician

Dima, expert washing machine repair technicianexperience8 years

Dima

Expert washing machine repair technician

We reply during working hours

Book display refrigerator repair in Almaty

Call us or leave a request on the website, and a technician will come to your display unit. Mention the refrigerator model and the nature of the fault — this speeds up diagnostics.

TECH SERVICE administrator replying to a customer's WhatsApp message

Warranty question? Call us

+7 (778) 746 00 26
Customer reviewsReviewsTECH SERVICE06

Reviews of display refrigerator repair in Almaty

Юлия А.Order No. ZK-2384 · 19 October 2026

ours

Долго откладывал ремонт, потом всё-таки собрался. Больше всего напрягало: шумит. Второй месяц — полёт нормальный)

Repair: display refrigerator repair in

Ляззат К.Order No. TS-6754 · 8 October 2026

ours

Больше всего напрягало: течёт. Никита М не стал навязывать дорогую запчасть, поставил нормальную. Крутит ровно, без рывков.

Repair: display refrigerator repair in

Максат О.Order No. ZK-8430 · 11 July 2026

ours

Прочитал кучу отзывов, половина — реклама, но тут вроде живые. Обратился по поводу холодильной витрины. Больше всего напрягало: шумит. Никита М снял деталь, показал износ, вопросов не осталось. Сначала сказали одно, потом уточнили, но в итоге всё совпало. Цену обсудили до начала, сюрпризов не было. Деталь на замену — вентилятор. Считаю, что нашёл своего мастера. Проверили при мне, показали, что всё держит.

Repair: display refrigerator repair in

Марина В.Order No. TS-2502-861 · 13 November 2025

ours

Больше всего напрягало: шумит. Дильмурат С не стал навязывать дорогую запчасть, поставил нормальную. Сделали и забыл про проблему.

Repair: display refrigerator repair in

Владимир Н.Order No. 39914 · 2 February 2023

ours

Проблема — не держит температуру. Дильмурат С снял деталь, показал износ, вопросов не осталось. Шум пропал, работает мягко.

Repair: display refrigerator repair in

Марат Ж.Order No. 2022-6200 · 7 December 2022

ours

Кепілдік мерзімі біткен соң бұзылды, әрине. Қосымша бөлшек қажет болды, бірақ бағаны көтермеді. Алдын ала айтқан уақыттан ерте бітірді. Бөлшектің бар-жоғын бірден тексерді, қоймада бар екен. Жұмыс барысын көрсетіп отырды, жасырған жоқ. Асыққан адамға ыңғайлы.

Repair: display refrigerator repair in

Павел Ш.Order No. 756915 · 8 August 2020

ours

Приехал из командировки, а дома — шумит. Приехал вечером, мастер ещё был на месте. Деталь на замену — вентилятор. Цену обсудили до начала, сюрпризов не было. Цену назвали не сразу, пришлось уточнять. Второй месяц — полёт нормальный)

Repair: display refrigerator repair in

Зарина Ш.Order No. 2019-5608 · 28 November 2019

ours

Пробовал найти мастера в своём районе, но все были заняты. Основная жалоба — не держит температуру. Никита М приехал в тот же день, хотя был конец смены. Включил, проверил, работает.

Repair: display refrigerator repair in

Юлия А.Order No. 513750 · 10 September 2019

ours

Техника на гарантии уже не была, так что выбор был свободный. Сначала думал, что ерунда, но появилось: шумит. Под замену пошло: термостат. Нагрев в норме, посторонних звуков нет.

Repair: display refrigerator repair in

Алмас Д.Order No. TS-1707-899 · 14 November 2017

ours

Позвонил знакомому, он раньше работал в сервисе, посоветовал этих. Проблема — шумит. Вернули в тот же день, всё функционирует)

Repair: display refrigerator repair in
Questions and answersQuestionsTECH SERVICE07

Questions about display refrigerator repair in Almaty

Didn’t find the answer? Message us on WhatsApp.

Ask a question
Can a display refrigerator be repaired right in the sales area?

Yes, we fix most display refrigerator issues on site: the technician comes to the store with their own tools. We only take the display unit to the service center if the circuit or compressor needs repair that can't be done in the sales area.

Why isn't the display refrigerator cooling even though the compressor is running?

If the motor is humming but there's no cold, it's usually a refrigerant leak, a clogged capillary, or a faulty fan. It depends on the model, so the technician will determine the exact cause after free diagnostics.

How can you tell if there's a refrigerant leak in the display case?

When there's a freon leak, the display case stops cooling, the compressor runs non-stop, and the evaporator gets uneven frost or stays warm. Sometimes there's an oily trace on the tubes, but the technician performs the exact leak detection.

What should you check if the beverage display is constantly humming and gets hot by evening?

Constant compressor operation and heating by evening are often due to a clogged condenser, worn door gasket, or refrigerant leak. Check if the condenser grille is blocked by products and if the door closes tightly; the technician will diagnose the rest.

The evaporator in the display case is covered in frost—what could have failed?

Evaporator frosting can be caused by a faulty fan, defrost sensor, timer, or heating element. It depends on the model: the technician will check the entire defrost circuit and give the exact cause after free diagnostics.

Do you clean the condenser of a display refrigerator during repair in Almaty?

Yes, the technician cleans the condenser and grille during display refrigerator repair in Almaty if it's clogged with dust. This helps the display case dissipate heat better, especially if it's located near an entrance from the street.

Repair guideArticleTECH SERVICE08

Display Refrigerator Repair in Almaty by Tech Service Technicians

Ruslan Ts., washing machine and refrigerator repair technician

Author: Ruslan Ts.,Washing machine and refrigerator repair technician

Published
Updated

Tech Service repairs beverage coolers, bakery cases and horizontal refrigerated display cases as a direct service provider: a technician with 4 to 20 years of experience arrives within 60 minutes anywhere in the city, and diagnostics are free. We fix most faults on site in the sales area and give a 1-year warranty on labor and parts.

How to read the symptoms of a failing display unit

A display unit almost always shows which component is failing — through shelf temperature, sounds and the way the compressor behaves. Below are the three scenarios shops bring to a technician most often, and what you can check yourself.

Why the shelves are warm while the compressor runs

When the shelves are warm while the compressor keeps humming, we trace it to three causes — a dust-clogged condenser, a stalled fan or a low refrigerant charge. The condenser releases heat into the room, and when its fins are covered in dust, system pressure rises, the motor runs without pauses and the cabinet gets less cold. The evaporator fan pushes air through the evaporator: if it stops, the cold stays at the back wall and the top shelves near the door warm up. A low charge looks different — frost covers only the first coils of the evaporator while the rest stays warm. Our technicians, with 4 to 20 years of experience, tell these cases apart by measuring pressure and temperature during the free diagnostics. If the unit holds the cold in the morning but weakens by evening, when the room is hotter, inspect the condenser grille first — dust produces exactly this pattern.

What clicking and failed start attempts mean

Repeated clicking without a start means the compressor is trying to start, but the start relay and the thermal overload keep opening the circuit. This is a familiar pattern in commercial refrigeration: the relay engages the start winding for a fraction of a second, and the overload cuts the motor when the current is too high and the housing overheats. That current has several possible causes — a worn relay, voltage drops on the shopping center's power line, a seized compressor, overheating from a dirty condenser. Testing starts with a multimeter rather than with swapping parts: the technician measures outlet voltage under load, winding resistance and relay condition. Quite often the power line itself is to blame, especially when several refrigerated cabinets and an air conditioner share one circuit. Do not keep switching such a unit on and do not move it to a thin extension cord — every failed start heats the compressor windings further and brings their burnout closer.

When noise and vibration point to a fault

  • Compressor knocking: metallic knocks inside the housing at start-up and shutdown are, in our view, a reason for diagnostics rather than waiting.
  • Fan whistling: a high-pitched sound at the back wall or inside the cabinet comes from worn motor bearings, and we replace such a motor as a whole.
  • Blade scraping: the blade hits ice, a price tag that fell behind a shelf or a shifted shroud — free its path and find the cause of the ice.
  • Cabinet rattling: vibration on an uneven floor and tubes touching the walls are fixed by the technician during the visit by adjusting the feet and mounts.
  • Constant hum: a steady noise that does not stop for hours signals an overloaded compressor — we check the condenser and door gasket first.

Where condensation, ice and water under the unit come from

Moisture is a common complaint from display case owners: drops on the glass, a layer of ice on the back wall, water on the floor. Each symptom has its own source, and it is easier to look for it in a set order.

Why the glass door fogs up

Condensation on the outside of the glass appears when the door surface is colder than the dew point of the air in the sales area. In summer and during rainy weeks indoor humidity rises, and even a working door gets covered in drops if the entrance is open nearby and a sink is in use. Many glass-door models have a heated frame, and sometimes a heated glass unit: a heating wire keeps the door edge above the dew point, and a break in it immediately leaves a wet strip around the perimeter. Condensation between the panes means the glass unit has lost its seal — only replacing it will help. Moisture inside the cabinet points to warm air passing through a worn gasket. Drops that vanish a few minutes after the door closes are a normal reaction of the glass to a flow of warm air. Wipe the glass dry and watch it for an hour: if drops gather along only one edge, check the gasket and heating on that side.

What to do if the evaporator is covered in ice

In our experience, a layer of ice on the evaporator most often points to a defrost failure, a stopped evaporator fan, a constant inflow of humid air through a loose door. In units with automatic defrost, the controller periodically switches on the defrost heater — simpler models just stop the compressor — and a sensor on the evaporator ends the cycle; if the heater burns out and the sensor reads wrong, ice builds up cycle after cycle. When the fan stops, cold air no longer passes through the fins, and they ice over much faster. Drafts from the entrance and frequent door opening add moisture that settles in the same layer. We check the heater, sensor and fan during free diagnostics and only then name the cause. Do not chip the ice off with sharp tools — it is easier to switch the unit off and let it melt, otherwise it is easy to puncture the aluminum evaporator tube and cause a leak.

How to find the source of a puddle under the unit

  • Drain channel: the opening under the evaporator clogs with residue, crumbs and ice, so meltwater overflows into the cabinet and runs out under the door.
  • Drip tray: water after defrost collects in a tray above the compressor and evaporates, while a crack or a shifted tray leaves a puddle at the back.
  • Drain tube: we find kinks, disconnections and clogs in the tube between the channel and the tray by inspecting the back and flushing with warm water.
  • Door gasket: excess moisture from the room turns into frost, melts during defrost and cannot drain away in time, so water appears at the front.
  • Normal versus warning: a little water in the tray after defrost is normal, while a constant puddle on the floor is always our reason to clean the drain.

Which display unit components we check and replace

A display refrigerator is built from several components, and each has its own typical failures. Testing goes in order so that working parts are not replaced and the real cause is found.

Display unit components and the work on them

ComponentSign of a faultWhat we do
CompressorWon't start, knocks, overheatsTest windings and relay, replace the unit
Condenser fanHot housing, shelves warmingClean the blades, replace the motor
Evaporator fanIce on the evaporator, warm topReplace the motor, free the blades
Controller and sensorsWrong temperature, code on the displayTest the sensors, replace the controller
Defrost heaterIce layer on the evaporatorMeasure resistance, fit a new one
Door gasketCondensation and frost at the doorMatch the profile, fit a new one
DrainWater in the cabinet, puddle on the floorClean the channel and tube
Refrigeration circuitWeak cooling, partial frostFind the leak, braze, recharge

How we repair the refrigeration circuit

We first locate the refrigerant leak, then braze the damaged spot, replace the filter drier, evacuate the system and recharge the circuit to the manufacturer's specification. Leak points in display units are typical: brazed joints near the compressor, the capillary tube, flare connections and the evaporator itself, which in some models is foamed into the cabinet. An electronic leak detector and soap solution are used for the search, and pressure is monitored with a manifold gauge set. The filter drier is always replaced after the circuit is opened: it has already absorbed moisture and no longer protects the system. Evacuation removes air and moisture; without it the new refrigerant works worse and the compressor wears faster. Charging follows the weight stated on the unit's rating plate and the operating pressure. Topping up without finding the leak is pointless — the refrigerant escapes again and the compressor keeps wearing itself out, so we do not offer that shortcut.

Electronics, sensors and lighting

The electronic controller switches the compressor on and off based on the cabinet temperature sensor, while a second sensor on the evaporator controls defrost. When the temperature sensor fails open, the unit shows an error code, freezes nonstop or never starts the compressor at all — the behavior depends on the model's firmware. A mechanical thermostat in simple beverage coolers fails differently: its contacts burn and the cabinet temperature starts to drift. LED lighting runs from a separate power supply and is not linked to cooling, although that power supply often fails after power surges. A multimeter and a reference thermometer let the technician compare the sensor reading with the real temperature on the shelves. Sensors are always tested before the controller is replaced: they are easier to replace and fail more often, and the code on the display frequently points right at them.

Repair without moving the unit out of the sales area

Most work on commercial refrigeration is done where the display unit stands. Below is what is done on site, when the service center is needed and how to prepare your shop for the visit.

What the technician does on site

We carry out display refrigerator repair in Almaty mostly right on site: a technician arrives within 60 minutes anywhere in the city, and the unit stays in the sales area. On site the technician replaces the start relay, fan motors, sensors and controller, the defrost heater and the door gasket, clears the drain and cleans the condenser. Brazing the circuit, replacing the filter drier, evacuation and recharging are also done on site if the tubes can be reached from the back. Compressor replacement is done there too — the unit only needs to be moved away from the wall. We work as a direct service provider: our own technician comes, with no middlemen and no passing your request to third parties. After the work, the technician checks that the cabinet reaches the set temperature and that the compressor cuts off by the sensor. Clear access to the back wall and outlet before the technician arrives — moving a loaded unit in a narrow aisle can be harder than replacing a part.

When a display unit needs repair at the service center

Repair at the service center is needed when the job requires fully dismantling the cabinet, long access to a foamed-in evaporator, conditions that the sales area cannot provide. This happens with a leak inside the walls, where tubes are hidden under insulation, with deep corrosion of the frame, with restoring the controller's electronic board. The technician decides on this format only after free diagnostics and explains what exactly cannot be done on site and why. Our technicians, with 4 to 20 years of experience, judge this by access to the component, not by a wish to save time. A small beverage cooler is easier to take to the service center, while a large horizontal display case is often better repaired on site, even if the job takes longer. Before deciding, ask the technician whether you will need a temporary replacement unit during the repair — this makes it easier to plan your product display.

How to keep your stock safe until the technician arrives

  • Move the stock: transfer perishables to a working refrigerator or cold room as soon as you notice the shelf temperature rising.
  • Keep the door shut: do not open the unit unless necessary — a closed cabinet holds the cold much longer than an open one.
  • Display readings: write down the error code and temperature and photograph the model plate on the cabinet, which speeds up diagnostics.
  • Cut the power: if you smell burning, see sparks or hear heavy compressor knocking, unplug the unit and wait for the technician.
  • Shelf thermometer: place a simple thermometer on the middle shelf and note the readings to compare them with the unit's sensor.
  • Access to the shop: let the shopping center security and the administrator know about the visit in advance, so no time is lost on a pass.

What the cost depends on and what the warranty gives you

The cost of the work is made up of the specific component and the scope of repair, while the warranty is the same for every format. Here is how the estimate is formed and when replacing a unit makes more sense than repairing it.

Why we quote the cost only after diagnostics

The technician quotes the repair cost after free diagnostics, once the faulty component, the required part and the scope of work are known. The total depends on the unit type, access to the component, the compressor model and whether the circuit needs brazing and recharging. Replacing a relay and clearing a drain is one category of work, while replacing a compressor with evacuation is quite another, so a phone estimate without an inspection remains only a rough guide for us. Shop owners comparing new display refrigerators and their price, which depends on cabinet volume and cooling type, can weigh it against the technician's estimate after diagnostics. We explain which components are worn and what can stay. Compare offers not by the first amount named but by the scope of work: for a circuit repair, the list should include replacing the filter drier and evacuation.

Repairing or replacing an old display unit

SituationSensible choiceWhy
Failed relay, sensor or fanRepairReplaced without opening the circuit
Leak at an accessible jointRepairBrazing and recharging on site
Worn gasket, clogged drainRepairSimple consumable parts
Compressor failure, sound cabinetUsually repairCabinet and circuit keep serving
Broken door hingeRepairThe hinge is replaced separately
Leak in a foamed-in evaporatorDecision after diagnosticsThe cabinet must be dismantled
Rust-through of cabinet and frameReplacementRestoration will not bring back the seal

What the warranty covers and how to pay

Tech Service gives a 1-year warranty on labor and parts for the completed work and installed parts, and the term is the same for repairs in the sales area and at the service center. We are a direct service provider: your display unit is inspected and repaired by our own technician with 4 to 20 years of experience, so the same service that ran the diagnostics is responsible for the result. You can pay via Kaspi QR, Kaspi Red, bank card, cash, or bank transfer for companies, so you can settle the bill in whatever way your shop's accounting uses. When choosing a technician for a commercial display unit, ask whether they have worked with your cooling type — static or fan-assisted — and which refrigerant the model uses: the tools and parts depend on it. The technician will show you the removed part and explain why it failed. Write down the unit model and the list of replaced components for yourself — if you call again, the technician will match the new symptom to the previous repair faster.

How to extend the life of a display unit in your shop

A commercial display unit works harder than a home refrigerator: the door is opened constantly, with dust, heat and drafts all around. A few simple habits noticeably reduce the load on the compressor and fans.

Cleaning the condenser and grille

We recommend cleaning the condenser of a commercial display unit with a soft brush and a vacuum cleaner after switching off the power. On beverage coolers the grille is most often at the bottom front, on some models at the back, and through it the fan draws in air along with dust, lint and small debris from the floor. If the shop sits at the entrance from a busy street or next to a bakery counter, where flour and grease hang in the air, the fins clog much faster than in an enclosed shopping center hall. A dirty condenser makes the compressor run longer and hotter, which shortens its service life. During free diagnostics our technician will show you where the grille is on your model and how to remove it without risking the tubes. Do not use water or pressure washers: moisture on the fan motor and start relay is more dangerous than dust, and bent fins release heat worse.

Where to place the display unit

A display unit needs free clearance to the wall and ceiling as specified in the manufacturer's manual, otherwise hot air from the condenser flows back to the grille. Direct sun through the shop window heats the cabinet and door, the compressor runs almost without pauses and the glass fogs up more. Heaters, air curtains at the entrance, ovens and coffee machines next to refrigeration equipment have the same effect, and for an open-front bakery case it is especially noticeable. The floor under the unit must be level: a tilt keeps the door from closing fully and disrupts meltwater drainage into the tray. It is best to give the unit its own outlet, without extension cords or splitters, so that voltage does not drop when the compressor starts. In summer, when the room is hot, check that the grille is not blocked by boxes and promo stands — blocked airflow quickly leads to compressor overheating.

Staff habits that protect the display unit

  • Loading the shelves: do not place goods tight against the back wall and air grilles, otherwise cold air will not reach the upper shelves.
  • Warm products: cool hot pastries and warm drinks first, otherwise the cabinet takes on moisture and the evaporator ices over faster.
  • Handling the door: stock the shelves in one go without leaving the door open for long, and check that it has closed tightly.
  • Gasket care: once a week wipe the gasket with warm water and look for cracks, tears and gaps around the perimeter.
  • Night mode: do not switch the unit off at night to save power — a stop that lets the cabinet warm up adds moisture and loads the compressor at every start.
  • Stickers and film: do not cover the ventilation slots and grilles of the cabinet with advertising, otherwise heat from the condenser escapes poorly.

What to remember about display refrigerator repair

A display refrigerator fails in predictable ways, and most symptoms point to a specific component. Here is a short summary of what a shop owner should remember.

  • The symptom points to the part: warm shelves, clicking, noise, condensation and puddles indicate different parts, so it helps to write down exactly what is happening.
  • Dust is worse than it looks: a dirty condenser overloads the compressor, and regular grille cleaning extends the life of the whole refrigeration system.
  • Ice is never chipped off: an ice layer on the evaporator is left to melt with the power off, and the cause of icing is traced to defrost and the fan.
  • The circuit needs a full cycle: after brazing, the filter drier is replaced, the system is evacuated, and only then is refrigerant charged to specification.
  • Installation matters a lot: clearance to the wall, shade, a level floor and a dedicated outlet reduce the load on the unit every single day.
  • Decide after inspection: repairing or replacing a display unit is chosen by the condition of the cabinet and circuit, not by the age of the model.

90brands

Which display refrigerator brands we repair in Almaty

We work with every brand sold in Kazakhstan — from Samsung, LG and Atlant to Biryusa, Indesit, Stinol and rare imported makes. Can’t find yours in the list? Call anyway — a technician will come and take a look.

We also repairWe also repairTECH SERVICE09

Besides display refrigerator repair, we fix other equipment in Almaty

Tech Service technicians repair other appliances too — with the same 1-year warranty on labour and parts.

BlogBlogTECH SERVICE10

Worth reading before display refrigerator repair in Almaty

Leave a review

Choose a platform — the TECH SERVICE page will open.

2ГИС2GISGoogle MapsЯYandex Maps
Send a review with photos on WhatsApp