Анастасия Т.Order No. AS-6485 · 10 August 2024
oursИскал, кто роботает в субботу, у нас с женой график сложный. Больше всего мешало: не холодит. Нагрев в норме, посторонних звуков нет.
City
Language
What broke
Sections
Message on WhatsApp+7 (778) 746 00 26Mon–Fri 10:00–19:00, Sat–Sun 11:00–18:00
A technician arrives within 60 minutes anywhere in the city. Diagnostics are free.
Our own technicians4 to 20 years of experience




Repair prices
Below are typical symptoms and likely causes. The technician will determine the exact cause during diagnostics.
Refrigerant leak, clogged filter
from10 000 ₸
Clogged drain, freezing
from7 500 ₸
Power supply, control board, remote
from14 000 ₸
Fan, mounting, bearing
from13 500 ₸
Mold on evaporator, clogged drain
from7 500 ₸
Refrigerant leak, compressor, sensor
from10 000 ₸
Overheating, clogged filters
from14 000 ₸
Batteries, receiver, control board
from14 000 ₸
The table lists the 'from' price for labor, for common jobs also the 'from' price of the part, plus the time required to complete the job.
1–2 hourstime
from 8 500 ₸cost

BeforeAfter5 steps

From request to performance check — five steps, with diagnostics included.
Submit a request by phone or messenger, describe the symptom.
The technician will arrive anywhere in the city within 60 minutes after confirmation.
The technician will check the components, identify the cause and repair cost.
Work is performed after you agree to the price and scope.
The technician will coordinate a convenient visit window and ask you to provide access to the indoor and outdoor units.
We reply during working hours
Submit a request by phone or messenger — the technician will arrive within 60 minutes anywhere in the city. Describe the symptom so the technician brings the right tools.

Warranty question? Call us
+7 (778) 746 00 266 127 reviews of repairs at TECH SERVICE in total
Анастасия Т.Order No. AS-6485 · 10 August 2024
oursИскал, кто роботает в субботу, у нас с женой график сложный. Больше всего мешало: не холодит. Нагрев в норме, посторонних звуков нет.
Вадим Г.Order No. TSA-38002 · 24 June 2024
oursСмотрел, чтобы был свой склад запчастей, а не под заказ. Сначала списал на мороз, но нет: ошибка. Никита М показал старую деталь, всё прозрачно. Сейчас пашет без нареканий
Вадим Г.Order No. AS-1535 · 5 May 2024
oursПричина обращения — течёт. Никита М всё сделал при мне, за пятнадцать минут. Астанинский Tech-service — нормальный вариант. Работает, даже лучше прежнего!!
Григорий И.Order No. AST-2207-665 · 28 October 2022
oursИскал, кто работает в субботу, у нас с женой график сложный. В работе было: сплит-система. Больше всего мешало: наледь. Перезвонили на следующий день, уточнили детали. Вышло около 34 500, точнее не считал. Обошлось заменой: плата. Сделали так, что и не придерёшься!!
Лариса О.Order No. ZK-2021-848 · 29 August 2021
oursС этим и пришёл: не холодит. Никита М разобрался в редкой модели. Ребята из techservice сидят в Астане давно. Шум ушёл, роботает мягко.
Ярослав С.Order No. ZK-2020-332 · 12 March 2020
oursЗнакомый мастер раньше здесь работал, дал номер. Ни с того ни с сего — не холодит. Никита М всё сделал при мне, за пятнадцать минут. Сделали так, что и не придерёшься.
Эдуард К.Order No. TSA-55276 · 7 February 2018
oursДруг из Сарыарки посоветовал это место. Сначала списал на мороз, но нет: не холодит. Ни разу не пожалел.
Михаил У.Order No. AS-2201 · 12 September 2016
oursРаньше обращался в другой сервис, там очередь на две недели. С чем обратился: не холодит. Даже сосед заметил, что громче не стало.
Степан Я.Order No. AS-1399 · 2 August 2016
oursСосед по площадке хвалил, решил проверить. Приняли в работу: кондиционер. С этим и пришёл: ошибка. Ни шума, ни запаха, всё штатно.
Каусар Ф.Order No. AS-2517 · 31 July 2016
oursҚұрылғы ескі, бірақ жақсы қарайды екен. Бағаны алдын ала айтты, соңында өзгермеді. Ақауын тез анықтады, қажетсіз нәрсе ұсынбады. Жұмысты сол күні аяқтады. Барлығы ресми, чек берді. Бөлшек қоймада бар екен, күтпедік. Диагностика тегін болды. Қосымша жұмыс қажет болды, бірақ бағаны көтермеді. Бәрі жақсы болды)
experience10 yearsAir conditioner refill technician
experience2 yearsAir conditioner cleaning technician
experience14 yearsAir conditioner chemical cleaning specialist
experience15 yearsMobile air conditioner technician
experience15 yearsLead HVAC specialist
Didn’t find the answer? Message us on WhatsApp.
Ask a questionAn inverter Toshiba holds the temperature more smoothly and is more efficient, but its board and compressor are more expensive to repair. A standard unit is simpler and cheaper to maintain, but it switches on and off more abruptly.
Toshiba units most often wear out the start capacitor, get a clogged drain, and lose refrigerant pressure due to a leak. Less often, the control board, sensors, and compressor fail — free diagnostics will pinpoint the exact cause.
Yes, after the Toshiba factory warranty expires, we repair them just like under warranty — the only difference is who pays for the parts. We provide a 1-year warranty on our labor and the parts we install.
A Toshiba inverter unit is usually repairable: the board, sensors, or compressor can be replaced, and that costs less than a new split system. Replacing the whole air conditioner makes sense when the component can't be restored or costs as much as a new unit — the technician will tell you after diagnostics.
First, the technician looks for a leak by pressure and by ear, checks the connections and flare fittings, fixes the cause, then vacuums the system and refills the refrigerant by weight. Only after that does the Toshiba cool and heat properly again.
In sub-zero outdoor temperatures, an inverter Toshiba may block heating to protect the compressor, or a sensor or board may be triggering. Diagnostics are needed to pinpoint the cause and fix it.

Author: Erlan Zh.,Air conditioner refill technician
Published
Updated
Tech Service repairs Toshiba air conditioners in Astana as a direct contractor with its own technicians. A technician arrives at your home within 60 minutes anywhere in the city or takes the unit to the service center. Diagnostics are free, and you get a 1-year warranty on labor and parts. The technician gives you the price after diagnostics.
The capital's climate puts a different kind of stress on an air conditioner than milder regions: winter heating and temperature swings are the main source of breakdowns we see on service calls.
In heating mode, a Toshiba runs at its limit longer than in cooling mode, and the outdoor unit regularly goes into defrost — this accelerates wear on the compressor and the four-way valve. An inverter unit smoothly adjusts power, but in sustained frost it almost never pauses, so the compressor accumulates running hours faster than in summer. The four-way valve switches the AC between cooling and heating, and every defrost cycle is an extra stroke for a mechanism sensitive to pressure changes. Temperature sensors control when defrost happens, and their readings get distorted while the outdoor unit is iced up. If the AC doesn't return to heating for a long time after defrost or freezes up again, that's no longer a winter quirk but a signal to check the valve and sensors before the load finishes off the compressor. Toshiba AC repair in Astana most often starts with exactly these winter symptoms.
Before the heating season, the AC needs heat exchanger and filter cleaning, a drain check, and a pressure check in the circuit so winter load doesn't catch the system in a weakened state. A clogged heat exchanger reduces heat transfer, and the compressor has to run longer at higher power. The drain is checked by pouring water through it: slow condensate removal in winter will turn into a leak or ice on the pipe. Circuit pressure shows whether the system holds refrigerant — a drop points to a leak that's best found before the first frost. It's also worth checking how the outdoor unit behaves at below-zero temperatures: early icing and long defrosts are the first sign that the valve or sensors are already off. This check takes little time but removes the main reason for winter service calls.
An error code on a Toshiba is a hint, not a verdict. Below we explain what's behind a blinking indicator and typical symptoms, and how a technician finds the real cause.
We decode the Toshiba error code by the pattern of indicator blinks and cross-check it against the condition of the components, because the same code can point to a sensor, the board, or the communication between units. On inverter models, the series of short and long flashes on the front panel adds up to a number that the manufacturer ties to a specific group of faults: air and heat exchanger temperature sensors, communication between the indoor and outdoor units, compressor current. The same signal reads differently on different series, so we match the combination against the service table for your exact model, not a generic cheat sheet from the internet. Recording the blink sequence before the technician arrives saves diagnostic time: it's easier to rule out false leads and check the right component right away instead of taking the whole unit apart.
We distinguish these faults by how the inverter unit behaves: if the compressor won't start or hums without turning while the board is sending commands, the cause is more often the compressor or the starting circuit, not the electronics. With working electronics, the outdoor unit responds to a command with a characteristic relay click and an attempt to spin the shaft—no rotation when voltage is applied points to the mechanical part or the winding. The opposite picture, when the compressor is fine but the board sends no signal, happens on inverter Toshiba units after voltage spikes: then a communication error shows on the display while the unit itself stays silent. A repeat error after a fix usually means the symptom was addressed, not the cause—for example, a sensor was replaced without checking the wiring and contacts—so we always test the component under load after replacement.
We structure Toshiba air conditioner repair in Astana as a clear sequence: request, free diagnostics, approval of the work, the repair itself, and a final check together with the owner.
During free diagnostics, we check the pressure in the circuit, the condition of the heat exchanger and drainage, the operation of the control board and sensors, and test both heating and cooling to name the exact cause. We run the check before any work on Toshiba air conditioners in Astana and look at the parameters in every mode, from cold start to defrost. We also inspect the drain pan and tube for clogs, check the terminal contacts, and assess the insulation integrity and the condition of the outdoor unit's fan. The technician quotes the price after diagnostics, because the same Toshiba error can require different amounts of work—from cleaning to replacing a component—and it's fairer to estimate based on the actual check rather than a description of the symptom.
Before recharging, we look for leaks and check the circuit's tightness, because without this the refrigerant will escape again and the compressor will keep running in a dangerous mode. Toshiba air conditioner repair in Astana often starts with finding microleaks at flare fittings and solder joints that aren't visible during a regular inspection. We check the circuit's tightness, inspect every connection, and after fixing the issue, top up the circuit with refrigerant to the required pressure. Tightness also matters because when refrigerant is low, the Toshiba inverter compressor runs at higher RPM and heats up more than usual. If there's a leak but it's not fixed, recharging only gives a temporary effect — so we first find and seal the leak, and check the pressure only after the circuit work is done.
We fix some Toshiba breakdowns right at the customer's address, while others require work in the workshop. Below is what determines the format and what to do with inverter models.
At the address, we fix leaks, clear drain clogs, replace sensors and starting components, clean the heat exchanger, and recharge refrigerant after fixing a leak — that is, work that doesn't require taking the unit apart in the workshop. The technician comes to your home, so they check the drain and condensate pan right away, and the circuit's tightness after the work. Replacing a temperature sensor or starting relay takes less time than the trip to the service center and back, and cleaning the heat exchanger also restores normal heat transfer and takes some load off the compressor. Around the city, the technician's visit takes 60 minutes. If after an external inspection the cause isn't obvious, the technician doesn't take the inverter unit apart "at random" at the customer's place but suggests a service center where the unit can be checked under calm conditions.
Toshiba units are taken to the workshop when work is needed on the control board, compressor, or inverter unit — these components require testing under load, which can't be done carefully on-site. The control board of an inverter model is connected to the compressor and sensors in a single circuit, and a diagnosis of "the compressor is at fault" without testing under load often turns out to be wrong: under load, you can see which component is failing and which is working normally. Replacing the starting part without testing the board under load leaves the risk of hidden defects that will show up weeks later. The decision to "repair or replace" an inverter unit depends on the condition of the compressor and board together: sometimes replacing one component doesn't help, and then it's more honest to discuss whether the work is worth doing before starting. We provide free diagnostics, so taking the unit apart doesn't turn into a separate expense.
| Type of work | Where we do it | What we check |
|---|---|---|
| Leak, clogged drain | On site | Drain, condensate pan |
| Refrigerant recharge | On site | Leak, tightness, pressure |
| Sensor replacement | On site | Readings, wiring |
| Control board repair | At the service center | Board under load |
| Compressor repair | At the service center | Compressor, starting components |
| Inverter block repair | At the service center | Inverter, compressor, board |
Warranty and the service provider matter more than speed — they determine what happens if the fault comes back. Below is how we stand behind Toshiba repairs and how a direct provider differs from an intermediary.
We provide a 1-year warranty on labor and parts, so if after service your Toshiba shows the same error again, we investigate the cause under this warranty. The term also covers replaced components: control board, inverter module, sensors, fan — everything we installed during the repair. A warranty on parts is as important as on labor: a hidden defect in a part can show up during operation, and the responsibility shouldn't shift to the owner. Some faults don't appear immediately but after weeks of use, so when replacing the board we also check the wiring to avoid having to open the unit again a month later. If the symptom returns after repair, the owner contacts us, and we recheck the same component without charging for the warranty inspection itself.
Tech Service is a direct provider with its own technicians, so the same service that performed the Toshiba repair is responsible for it, with no chain of intermediaries between you and the technician. Our specialists have been working with this brand for 4 to 20 years and arrive on site within 60 minutes anywhere in the city. With an aggregator, responsibility is blurred between the platform and the contractor: one system takes the request, and a contractor you didn't choose shows up at your door. With a direct service, the warranty is backed by one team that already knows your air conditioner's history — which components were replaced and what to look for next time. When choosing a technician by brand, ask not only about experience but also who exactly will come and who is responsible for the warranty — that matters more than response speed.
Repairing a Toshiba air conditioner comes down to precise diagnostics, not replacing parts at random. Below is what determines the outcome and helps you avoid paying twice for the same breakdown.
80brands
We work with air conditioners and split systems of every brand sold in Kazakhstan — from Almacom, Gree and Midea to LG, Samsung, Chigo and rare imported makes. Can’t find yours in the list? Call anyway — a technician will come and take a look.
Tech Service technicians repair other appliances too — with the same 1-year warranty on labour and parts.
Refrigerator Repair in Almatyfrom 3 000 ₸
Washing Machine Repair in Almatyfrom 3 000 ₸
Dishwasher Repair in Almatyfrom 3 500 ₸
Oven Repair in Almatyfrom 3 000 ₸
Cooktop Repair in Almatyfrom 3 500 ₸
Air Conditioner Repair in Almatyfrom 3 500 ₸
Boiler and Water Heater Repair in Almatyfrom 2 500 ₸
Freezer Repair in Almatyfrom 6 000 ₸
Tumble Dryer Repair in Almatyfrom 5 000 ₸
Coffee Machine Repair in Almatyfrom 2 500 ₸
Robot Vacuum Cleaner Repair in Almatyfrom 3 500 ₸
Vacuum Cleaner Repair in Almatyfrom 1 500 ₸
Microwave Oven Repair in Almatyfrom 2 000 ₸
Hair Dryer Repair in Almatyfrom 1 500 ₸
Iron Repair in Almatyfrom 3 000 ₸
Electric Kettle Repair in Almatyfrom 2 500 ₸
Mixer Repair in Almatyfrom 2 500 ₸
Multicooker Repair in Almatyfrom 500 ₸
Air conditioner errors are codes on the display or flashing indicators that show which component has failed.
5 March 2026 · 12 minutes read
If your air conditioner is leaking, first turn it off and cut the power, place a container under the drip, and move any wiring away from the water.
19 October 2025 · 12 minutes read
Gas boiler errors are codes on the display or a flashing indicator that point to a specific component: ignition, pressure, draft, sensor, or control board.
10 February 2026 · 11 minutes read