Любовь Ю.Order No. ZK-2026-452 · 24 August 2026
oursДамир М провозился, но сделал. Астанинский Tech-service — нормальный вариант. Дома включил, всё на месте.
City
Language
What broke
Sections
Message on WhatsApp+7 (778) 046 88 53Mon–Fri 10:00–19:00, Sat–Sun 11:00–18:00
A technician arrives within 60 minutes anywhere in the city. Free diagnostics, 1-year warranty on labor and parts.
Our own technicians4 to 20 years of experience




Repair prices
Below are typical symptoms, their likely causes, and the stage at which the technician will pinpoint the exact fault.
clogged filter, frozen heat exchanger
from7 000 ₸
no power, faulty board
from12 000 ₸
clogged drain, cracked pan
from19 500 ₸
loose compressor mount
from27 500 ₸
code points to a specific component
from10 500 ₸
faulty humidity sensor, stuck relay
from10 500 ₸
clogged filter, dirty heat exchanger
from8 000 ₸
refrigerant leak, defrost sensor failure
from15 500 ₸
Choose a tab with a symptom or service to see the relevant price list items.
1–2 daystime
from 13 500 ₸cost

BeforeAfter5 steps

Five steps from your request to checking the appliance's operation.
You describe the problem, the technician confirms the model and agrees on the address.
The technician finds out where the dehumidifier is located: in a living space, basement, or construction site.
You approve the list of faults and scope of work, after which the technician begins.
The technician performs the agreed work and checks the components together with you.
The technician shows what has changed after the work and gives you recommendations for the coming season.
We reply during working hours
Before calling, have the dehumidifier model, a description of symptoms, and the type of room ready. If your plans change, let the technician know in advance to reschedule the visit.

Warranty question? Call us
+7 (778) 046 88 536 127 reviews of repairs at TECH SERVICE in total
Любовь Ю.Order No. ZK-2026-452 · 24 August 2026
oursДамир М провозился, но сделал. Астанинский Tech-service — нормальный вариант. Дома включил, всё на месте.
Айша О.Order No. AS-2425 · 6 April 2026
oursАстанада тұрамын, қаланың арғы жағына бару ыңғайсыз болды. Қабылдау тез болды, кезек жоқ.
Римма Х.Order No. 95597 · 22 December 2025
oursНикита М всё сделал при мне, за пятнадцать минут. Стоит, работает, радует
Мария Р.Order No. AST-2511-819 · 7 September 2025
oursЗимой без техники никак, поэтому тянуть было нельзя. Думал, показалас, ан нет: шумит. Дамир М не пропал после ремонта, помог с настройкой. Перезвонили на следующий день, уточнили детали. Вскрытие показало: компрессор. По деньгам вышло ровно, без сюрпризов. Работает, как будто и не ломалось.
Олег Х.Order No. 93048 · 4 March 2025
oursПричина обращения — не собирает влагу. Никита М разрулил всё быстро. Ни разу не пожалел.
Шынар М.Order No. AST-2304-605 · 29 August 2023
oursҚыс қатты, техникасыз қиын, сондықтан тез жөндеу керек болды. Қабылдау тез болды, кезек жоқ. Жұмыс істеп тұр, шағым жоқ.
Людмила Щ.Order No. ZK-2022-925 · 4 August 2022
oursДамир М подобрал аналог дешевле, не навязывал оригинал. Отдал 26 500 и не жалею. Работает, даже лучше прежнего
Софья Ц.Order No. AS-9635 · 16 January 2022
oursНикита М разобрался в редкой модели. Полёт нормальный. После ремонта — как новое.
Софья Ц.Order No. AS-2942 · 31 December 2021
oursДруг из Сарыарки посоветовал это место. Больше всего мешало: шумит. Третий месяц — никаких проблем
Аркадий Я.Order No. ZK-2021-648 · 4 November 2021
oursПозвонил в четыре места, тут ответили по-человечески. После скачка напряжения — шумит. Дома включил, всё на месте.
Борис В.Order No. AS-2741 · 9 April 2021
oursТехника на балансе ТОО, нужен был чек и акт. С этим и пришёл: не собирает влагу. Дома включил, всё на месте.
Геннадий Ж.Order No. 2009-1393 · 23 December 2020
oursВ Астане с сервисами беда, поэтому выбирал по отзывам. В работе было: осушитель воздуха. Больше всего мешало: не собирает влагу. Никита М показал старую деталь, всё прозрачно. Приговор — компрессор. Ни шума, ни запаха, всё штатно.
Василий Е.Order No. AST-2011-714 · 14 December 2020
oursС этим и пришёл: шумит. Никита М подобрал аналог дешевле, не навязывал оригинал. Крутит ровно, без рывков.
Римма Х.Order No. 80022 · 17 November 2020
oursДамир М сам позвонил и сказал, что готово. За такую работу 24 000 — адекватно. Стоит, работает, радует
Фёдор Б.Order No. 86894 · 21 January 2020
oursИскал, кто работает в субботу, у нас с женой график сложный. После скачка напряжения — не собирает влагу. Вышло из строя: компрессор. 34 500 за работу и деталь, считаю нормально. Приняли вечером, хотя до закрытия оставалось минут десять. Нагрев в норме, посторонних звуков нет)
Валерий Д.Order No. ZK-2020-146 · 4 January 2020
oursВ Астане с сервисами беда, поэтому выбирал по отзывам. Основная жалоба — не собирает влагу. Внешне не видно, что разбирали.
Елизавета Л.Order No. AS-1476 · 8 October 2019
oursТехника на балансе ТОО, нужен был чек и акт. Основная жалоба — шумит. Никита М подобрал аналог дешевле, не навязывал оригинал. Позвонил в Tech-service по номеру из 2ГИС. Ни разу не пожалел.
Инна Н.Order No. ZK-2019-401 · 31 May 2019
oursСмотрел, чтобы был свой склад запчастей, а не под заказ. Не люблю эти поездки по сервисам, но деваться некуда. Причина обращения — не собирает влагу. Никита М разобрался в редкой модели. Стоит, работает, радует.
Людмила Щ.Order No. TSA-84152 · 26 September 2018
oursИскал, кто работает в субботу, у нас с женой график сложный. Больше всего мешало: шумит. Никита М разрулил всё быстро. Тихо, ровно, без сюрпризов.
Вера Э.Order No. TSA-42948 · 23 December 2017
oursБыло важно успеть до конца недели, а то морозы обещали. Первое, что заметил: шумит. Проверил на всех режимах — держит
experience14 yearsSenior small appliance technician
experience15 yearsOn-site coffee machine diagnostics technician
experience5 yearsCoffee machine cleaning technician
experience12 yearsCoffee machine diagnostics technician
experience5 yearsPortafilter coffee machine technician
experience12 yearsVacuum cleaner repair technician
experience15 yearsVacuum cleaner repair technician
experience18 yearsWashing machine repair technician
Didn’t find the answer? Message us on WhatsApp.
Ask a questionThe usual cause is the compressor, a refrigerant leak, or a clogged evaporator: the circuit doesn't cool, so no condensation forms. A free diagnostic will show exactly what's broken.
Yes, if the unit is working properly and running normally: it simply lowers the humidity. But if the dehumidifier is faulty, leaking, or very noisy, it's better to turn it off and have a technician look at it.
Don't place it right against a wall, in damp corners, or near heat sources: airflow gets blocked and the unit overheats. If your appliance was already placed that way and broke down, that could be the cause.
Humming without cooling often points to the compressor or a refrigerant leak, but the technician gives an exact verdict after inspection. It depends on the model and the condition of the component.
Yes, it's best to turn the unit off: water on the floor and near wiring risks a short circuit, and the leak itself points to a clogged drain or a shifted tray. A technician will determine the cause on site.
First check the outlet, the cable, and the power button: sometimes it's just a break in the line. If there's no response, it's a fault in the board or compressor, and a technician needs to come out.
Tech Service repairs air dehumidifiers in Astana as a direct contractor, with no middlemen. Our technician arrives at your home within 60 minutes anywhere in the city or takes the unit to our service center. Diagnostics are free, we provide a 1-year warranty on labor and parts, and the technician gives you the price after inspection.
Owners come to us with a symptom, not the name of the fault: it's silent, not collecting water, leaking, or humming. Let's look at four common scenarios and the technical causes behind them.
Most often the control board, humidity sensor, or the effects of a power surge are to blame. The control board receives a signal from the sensor and starts the compressor together with the fan; if a trace or relay burned out after a voltage spike, the unit won't come out of standby mode. If the humidity sensor's circuit is broken, it gives incorrect readings, and the logic blocks startup, assuming the air is already dry. Long periods of disuse add their own cause: contacts stick, connectors oxidize, and the motor's start relay loses sensitivity. Diagnostics for air dehumidifier repair in Astana begins with measuring the input voltage and testing the sensor — these two components rule out half of the false leads. If the device is silent after a long idle period, don't rush to disassemble the case — first check the power supply and sensor, and diagnose the electronics separately.
In a condensing dehumidifier, moisture settles on the evaporator, so a "dry" result usually points to a refrigerant leak, a clogged heat exchanger, or weak heating. The compressor circulates refrigerant through the circuit, the evaporator cools and condenses moisture from the passing air; if there's a leak, the cold disappears, and the fan just blows dry air around. A heat exchanger clogged with dust gives the same effect: the fins don't transfer cold, and condensate doesn't form. Another cause is a faulty humidity sensor that keeps the motor off when the room is actually humid. Before talking about replacing the power unit, the technician checks whether cold reaches the evaporator — sometimes restoring the cooling circuit is enough. If there is cold but no condensate forms, we check the drainage and the position of the drip tray: water may be bypassing the tank.
A puddle under the unit is most often related to the drainage system, the drain tank, or the condensate pump, while humming without cooling points to the power unit. The drainage system directs condensate into the drain tank; a cracked hose, a displaced tube, or an overflowing tank without a float will send water onto the floor. A clogged condensate pump runs dry and overheats, and its impeller eventually gets coated with deposits. Humming that appears along with a loss of cooling is a sign of motor wear or its start relay. If water is leaking onto the floor, it's best to unplug the unit right away — moisture near the control board turns a minor fault into a electronics replacement. After unplugging, lift the unit so water doesn't get inside the case, and wipe the drip tray dry.
The code on the display is a hint, not a verdict: it points to a component but doesn't name the broken part. Let's look at how to interpret the signal without a manual and what happens during free diagnostics.
An error code on the display points to a component, not a specific part, so the interpretation is always checked against the unit's behavior. The control board displays a combination based on sensor readings: humidity, temperature, condensate level, compressor current. The same code can mean different things on different models — on one it's a drainage overflow, on another a fan failure. It helps to recall what the unit was doing before it stopped: humming, clicking, running without collecting water, or shutting off after a couple of minutes. The technician looks at the combination of code, symptom, and history, not just a single number. If the signal repeats after a restart, don't reset it repeatedly — that erases the history that shows the cause.
We start with power and the humidity sensor, then move on to the compressor, fan, and control board — this way simple causes are ruled out before disassembling the case. On arrival, we test the cable and measure voltage at the board terminals, and compare the humidity sensor readings with a hygrometer: sensor drift causes a false error and stops dehumidification. We inspect the drainage system — tray, tube, and pump — for clogs and kinks, because they most often cause leaks and the overflow code. On the fan, we check blade rotation and motor current: jamming stops dehumidification and overheats the compressor. We only move to the compressor after ruling out simple causes — we check startup, current, and pressure in the circuit, and inspect board contacts and connectors for overheating and oxidation if other components are fine. This order saves the customer time: if the sensor is faulty or the drain is clogged, the work is done on site.
A dehumidifier doesn't always need to be taken to the workshop: some breakdowns are fixed on site while the unit is still in the apartment. Here's what can be done at home and what requires in-shop service.
We take the unit to the service center when it can't be fixed on site: compressor replacement, work on the cooling circuit, complex control board repair. The compressor is the heart of the dehumidifier: if it won't start, overheats, or runs intermittently, the circuit needs vacuuming, refrigerant replacement, and pressure testing, which is only possible in a service center. Such operations aren't done at home due to lack of equipment and the risk of damaging the circuit, so the unit is transported to the workshop. The board is sent to the workshop when the damage affects multiple layers of traces or the microcontroller: such work is performed in a service center. In-shop service covers the full scope of cooling circuit work that can't be done at home. The technician mentions the need for in-shop service right after free diagnostics, so the customer understands the cause rather than learning it after the fact, and can plan repair timelines in advance.
A technician arrives within 60 minutes anywhere in the city, not just downtown — all of Astana is covered, from the left bank to the outskirts. We plan the route in advance so the specialist doesn't get stuck in rush-hour traffic. Residents of new neighborhoods get the same technician as the city center — we don't divide visits into near and far addresses. If the unit is leaking or smells like something is burning, it's best to unplug it right away and not wait for the visit, so the problem doesn't get worse. This is especially important when moisture has already reached the outlet or the neighbors downstairs, and the dehumidifier is still running. Before the technician arrives, don't try to take the case apart yourself — you could damage parts that are still repairable.
Two concerns come up most often from appliance owners: overpaying a middleman and being left without a warranty if something goes wrong. Let's address both — who actually shows up, what the warranty covers, and how payment works.
Tech Service is the direct service provider: our own staff technician comes to you, not a contractor from an aggregator, so we're responsible for the result, not a third party. Our specialists have 4 to 20 years of experience with dehumidifiers and arrive at your address within 60 minutes anywhere in the city. We don't take a request and pass it on — diagnostics, repair, and warranty obligations are all handled by the same organization. An aggregator works differently: it connects the client with an unknown contractor and takes a commission, while the quality of work stays outside its control. When the work is done by a direct service provider, there's no dispute over who's to blame between the middleman and the technician — responsibility for the result is in one place. So when choosing a contractor, ask who will physically arrive and who will sign the warranty: if the answers don't match, you're dealing with a middleman.
We provide a 1-year warranty on labor and parts — this applies to both in-home service and work at our service center. The terms are the same for both: whether the issue was fixed on site or the unit was taken in, the warranty period doesn't change. A warranty on parts is just as important as on labor: if a part fails early, the client doesn't pay for it again. Many people overlook this and accept verbal promises — then when the same problem comes back, it turns out no one covers the replaced component. Ask for the warranty to cover the installed components, not just the fact that the work was done. That way, a repeat failure of the compressor, fan, or control board doesn't turn into a new procedure at your expense.
The technician gives you the price after a free diagnostic, once the cause is known, and you can pay any way you like — via Kaspi QR, Kaspi Red, bank card, cash, or bank transfer for companies. This approach removes the main risk: you don't agree to work blindly and don't find out the amount after disassembly has already started. First, the specialist identifies the problem, explains which component failed and what to do about it, then gives you the total for labor and parts. The client sees what they're paying for before work begins: first the cause and scope, then the decision — to go ahead or not. You can decline at this point with no consequences, and the diagnostic is free either way. In my opinion, transparent pricing is what separates a good service from one where the amount is announced after the fact.
Some dehumidifier care tasks you can do yourself, others require disassembly and tools. Here's where prevention ends and a breakdown begins — the point where you need a technician.
If the unit still doesn't collect water or is noisy after cleaning, the issue isn't dirt but a component — the compressor, fan, or sensor. A dust-clogged mesh explains weak airflow but not the lack of condensate: the compressor and heat exchanger are responsible for moisture removal, and the humidity sensor ensures proper shutdown. When the unit hums but no water drips, or conversely runs quietly and doesn't dry, the cause is almost always inside the housing. Trying to flush deeper without disassembly often damages the heat exchanger — the fins bend easily and the circuit's seal can break. At this point, it's better to stop and call a technician: free diagnostics will show exactly what failed, and you won't have to pay extra for a damaged component.
We recommend checking the filter and drainage regularly, and leaving full heat exchanger service to a technician — especially if the unit runs under heavy load. The fan, compressor, and humidity sensor require careful disassembly, so we handle that part: a technician comes to your home or services the unit at the shop, and provides a 1-year warranty on labor and parts. In a dry climate, a dehumidifier works harder, so maintenance is less often put off — a clogged heat exchanger makes itself known sooner, and clogged fins reduce moisture removal and force the compressor to run longer without a break. For city residents, remember: the sooner you check the filter and drainage, the less often you'll need to call a technician for an emergency breakdown.
We explain which types of units people bring to us, why long periods of disuse and voltage surges are risky, and what to do if your dehumidifier is still under the manufacturer's warranty.
| Dehumidifier type | How it collects moisture | What we check most often |
|---|---|---|
| Condensation | condenses on the evaporator | compressor, refrigerant, heat exchanger |
| Adsorption | absorbed by a sorbent | heating element, fan |
| With hygrostat | based on set humidity | humidity sensor, control board |
| Office | like household, higher load | drainage, condensate pump |
After long periods of disuse or a power surge, the control board and compressor are the most common casualties — the unit may fail to turn on or hum without cooling. A surge in the grid damages the power components on the board, and the electronics stop sending start commands; the motor itself remains functional but receives no signal. During idle periods in an unheated space, the unit itself suffers too: the oil thickens, and on a sudden start the load on the windings increases. Humming without cooling usually points to a seized rotor or start relay. If the equipment has been sitting unused, don't fire it up at full power right away — better to have a technician check the power supply and electronics before running it continuously. Our experience shows that often only one component needs replacing, not the whole unit.
If the unit is under the manufacturer's warranty, it's best to start with that warranty, and having us repair it is an option for when the obligations no longer apply or the wait is too long. Warranty obligations are tied to the seller or manufacturer and require following their established procedure, so it makes sense to start with the purchase documents and their terms. Disassembling the housing yourself often voids the manufacturer's warranty, so before making a claim, it's better not to open the unit or remove seals. Once the warranty period has expired, diagnostics with us are free: the technician will identify the cause and quote the cost of work before starting. A broken seal from a DIY repair attempt often forfeits the right to free defect correction under the manufacturer's warranty.
Dehumidifier repair comes down to pinpointing the component that has failed. Below is a quick summary to help you avoid overpaying and prevent the problem from getting worse.
10brands
Choose a brand to go to a dedicated page describing the work for that brand.
Tech Service technicians repair other appliances too — with the same 1-year warranty on labour and parts.
Refrigerator Repair in Almatyfrom 3 000 ₸
Washing Machine Repair in Almatyfrom 3 000 ₸
Dishwasher Repair in Almatyfrom 3 500 ₸
Oven Repair in Almatyfrom 3 000 ₸
Cooktop Repair in Almatyfrom 3 500 ₸
Air Conditioner Repair in Almatyfrom 3 500 ₸
Boiler and Water Heater Repair in Almatyfrom 2 500 ₸
Freezer Repair in Almatyfrom 6 000 ₸
Tumble Dryer Repair in Almatyfrom 5 000 ₸
Coffee Machine Repair in Almatyfrom 2 500 ₸
Robot Vacuum Cleaner Repair in Almatyfrom 3 500 ₸
Vacuum Cleaner Repair in Almatyfrom 1 500 ₸
Microwave Oven Repair in Almatyfrom 2 000 ₸
Hair Dryer Repair in Almatyfrom 1 500 ₸
Iron Repair in Almatyfrom 3 000 ₸
Electric Kettle Repair in Almatyfrom 2 500 ₸
Mixer Repair in Almatyfrom 2 500 ₸
Multicooker Repair in Almatyfrom 500 ₸
If your dishwasher won't drain, the most common culprits are a clogged filter or drain hose; less often, it's the pump, impeller…
24 March 2026 · 12 minutes read
A washing machine can hum for many reasons, and the first thing to figure out is when the sound appears.
20 March 2026 · 12 minutes read
The easiest way to remove scale from a kettle is with citric acid: 1–2 tablespoons per liter of water, boil for 5–10 minutes, then drain and rinse.
17 March 2026 · 13 minutes read
If your laptop screen is broken, turn the device off first, don't press on the display, and check the picture through an external monitor.
12 March 2026 · 11 minutes read
Air conditioner errors are codes on the display or flashing indicators that show which component has failed.
5 March 2026 · 12 minutes read
If your washing machine isn't filling with water, the most common culprits are a closed valve, a clogged inlet filter screen on the hose…
20 February 2026 · 13 minutes read