Семён Ш.Order No. AST-2512-345 · 23 August 2025
oursДамир М отсоветовал дорогой ремонт, предложил простой. Обошлось заменой: плата. Тихо, ровно, без сюрпризов)
City
Language
What broke
Sections
Message on WhatsApp+7 (778) 746 00 26Mon–Fri 10:00–19:00, Sat–Sun 11:00–18:00
Free diagnostics and a technician at your door within 60 minutes anywhere in the city. 1-year warranty on labor and parts.
Our own technicians4 to 20 years of experience




Repair prices
Below are typical symptoms, their likely causes, and what the technician checks after diagnostics.
Filter, refrigerant leak, compressor
from10 000 ₸
Drainage, dirt buildup, tilt
from7 500 ₸
Power supply, board, remote
from14 000 ₸
Code points to a component
from14 000 ₸
Mounting, fan, compressor
from13 500 ₸
Heating element, sensor, compressor
from8 500 ₸
Overheating, sensor, board
from8 500 ₸
Batteries, receiver, board
from14 000 ₸
The table lists the 'from' price for labor, for common jobs also the 'from' price of the part, plus the time required to complete the job.
1–2 hourstime
from 8 500 ₸cost

BeforeAfter5 steps

Five steps from request to checking the air conditioner's operation.
The technician compares your observations with the actual behavior of the unit and the error code.
The technician finds a convenient time slot and confirms the address.
The technician clarifies what needs to be cleared near the wall and how access to the drainage and piping will be arranged.
The technician turns on the air conditioner in different modes and shows that the symptom is gone.
The technician removes debris and returns the unit to its working position.
We reply during working hours
Describe the fault and a convenient time. The technician will schedule the visit and name the necessary parts before work begins.

Warranty question? Call us
+7 (778) 746 00 266 127 reviews of repairs at TECH SERVICE in total
Семён Ш.Order No. AST-2512-345 · 23 August 2025
oursДамир М отсоветовал дорогой ремонт, предложил простой. Обошлось заменой: плата. Тихо, ровно, без сюрпризов)
Валентина Р.Order No. AS-3804 · 14 April 2024
oursВ Астане с сервисами беда, поэтому выбирал по отзывам. Больше всего мешало: не холодит один блок. Гудит ровно, не перегреваеться!!
Юрий М.Order No. TSA-86858 · 30 March 2024
oursНикита М провозился, но сделал. Выбрал techservice, потому что близко к работе. Третий месяц — никаких проблем)
Маргарита П.Order No. AST-2304-733 · 8 June 2023
oursПозвонил насчёт сплит-системы. Основная жалоба — не холодит. Замена: компрессор. Цену держали до конца, молодцы. Мастер сам предложил забрать технику на следующий день. Крутит ровно, без рывков.
Михаил У.Order No. TSA-98207 · 19 April 2023
oursДамир М показал старую деталь, всё прозрачно. Обошлось заменой: дренаж. Внешне не видно, что разбирали
Василий Е.Order No. 69402 · 29 March 2022
oursПозвонил в четыре места, тут ответили по-человечески. Открыл — и сразу понял: течёт. Дамир М всё сделал при мне, за пятнадцать минут. Выдали номер заказа и сказали, как отслеживать. Нагрев в норме, посторонних звуков нет.
Семён Ш.Order No. TSA-89364 · 10 January 2022
oursЧестно, не ожидал, что так быстро. Симптом как на ладони: ошибка. Тихо, ровно, без сюрпризов.
Оксана Т.Order No. AS-2569 · 13 December 2020
oursЗимой без техники никак, поэтому тянуть было нельзя. Ни с того ни с сего — наледь. Дамир М отсоветовал дорогой ремонт, предложил простой. Вернули — проверил, всё ок.
Валерий Д.Order No. AST-1904-431 · 4 December 2019
oursДруг из Сарыарки посоветовал это место. Первое, что заметил: не включается. Проверил на всех режимах — держит.
Аркадий Я.Order No. AST-1904-952 · 29 July 2019
oursЗаявку оставил через сайт вечером, утром перезвонили. С чем обратился: наледь. Работает, как будто и не ломалось)
experience10 yearsAir conditioner refill technician
experience2 yearsAir conditioner cleaning technician
experience14 yearsAir conditioner chemical cleaning specialist
experience15 yearsMobile air conditioner technician
experience15 yearsLead HVAC specialist
Didn’t find the answer? Message us on WhatsApp.
Ask a questionLG air conditioners are made by the South Korean company LG Electronics. The brand is known for its inverter models, which require qualified repair when they break down.
Reliability depends on the model and operating conditions, not just the brand. LG is one of the popular manufacturers, but any air conditioner needs maintenance and timely repair.
Most often the cause is a refrigerant leak, a clogged filter, or a faulty sensor, and less often the compressor. Free diagnostics will pinpoint the exact cause, and after that the technician will give you the cost and repair plan.
In freezing weather, the outdoor unit of an inverter model gets covered in frost and goes into protection mode, especially with incorrect settings or low refrigerant. The technician will check the sensors, drainage, and circuit pressure to restore normal operation.
In a properly working system, refrigerant is not consumed, so refilling is only needed after fixing a leak. If cooling is lost, the cause is found first, and only then is refrigerant added—otherwise the problem will come back.
Yes, age alone is not a reason to give up on repair: much depends on the model and the condition of the components. During diagnostics, the technician will assess wear and tell you what is more cost-effective—repairing the component or replacing it.

Author: Erlan Zh.,Air conditioner refill technician
Published
Updated
Tech Service repairs LG air conditioners in Astana: a technician comes to your home within 60 minutes or the work is done at our service center. Diagnostics are free, we give you the price after diagnostics, and there's a 1-year warranty on labor and parts. Technicians with 4 to 20 years of experience will decode the error code and fix the root cause.
A code on the display isn't a death sentence—it's a hint from the unit itself. Let's break down what common LG signals mean and when you actually need a technician versus when a correct setting is enough.
| Code / signal | What we check | Common cause |
|---|---|---|
| CH | communication between the board and indoor unit | broken wire or module failure |
| Blinking indicator | air temperature sensor | sensor failure |
| Drain error | drain pump and tube | clog, condensate buildup |
| Compressor error | start-up assembly, windings | wear, voltage spike |
| Communication error | inverter module | electronics failure |
Some LG signals clear with a reset and correct mode setting, but a code that repeats after reset is a sign of a real fault. The LG control board manages modes and polls temperature sensors: if the remote is set to an incompatible mode or the settings are off, the electronics throw an error without any physical failure of a component. A reset restores factory parameters, and some signals go away. A different story is a code that stays or returns after a few cycles: here we check the sensor itself, the connectors, and the board's integrity. We do diagnostics for free and start with decoding the signal, not by taking the unit apart. If the error returns after a restart, don't keep running the air conditioner hoping it will go away—repeated starts with a faulty component speed up wear and expand the damage.
If your LG air conditioner shows the same error after service, we recheck the component under warranty and look for the cause, not just the symptom. The 1-year warranty on labor and parts also covers a repeat visit for the same code: the technician tests the unit again and compares sensor readings with the reference. A repeat signal often means the effect was fixed, not the source—for example, the sensor was replaced but the cause of its overheating wasn't found, or a connector was repaired but the control board still gets distorted data. That's why we test in several modes after work, not just on power-up. An honest review of a repeat case is cheaper than a series of random replacements.
An LG owner usually describes a symptom, not a component: "not cooling," "water leaking," "humming." Each signal has a specific cause—let's look at what we check first.
If your LG blows but doesn't cool, we first look for a refrigerant leak and only then check the compressor—that way we avoid replacing an expensive component unnecessarily. The technician inspects the refrigerant line along its entire length, including flare connections and brazed joints, measures pressure in the circuit, and assesses whether the unit holds working pressure at start-up. Often the refrigerant escapes through a microcrack at a connection, and the compressor itself is fine. The compressor fails less often—as a result of long operation with a leak or power supply issues. Recharging without finding the leak gives a temporary effect: the refrigerant will escape again through the same spot. That's why we inspect the line before recharging and fix the cause, not just top up the circuit.
A leak from the indoor unit of an LG air conditioner is usually caused by the drainage system — a clogged pipe or a failed drain pump — rather than by refrigerant. The technician removes the front panel, checks the drain pan for dirt, blows out the condensate drain pipe, and tests the pump if the model has one. Another common cause is a misaligned unit tilt during installation: water doesn't reach the drain and overflows the pan. We inspect the heat exchanger for dirt — a clogged evaporator freezes and releases water abruptly during defrost. If moisture appears only in humid weather, it's worth checking the drain slope and the cleanliness of the heat exchanger: a clogged evaporator collects more condensate than the pipe can drain. This check often resolves the issue without disassembling the refrigeration circuit.
Noise and vibration in an LG unit usually come from the fan or the mounting of the units, and after a power surge we first check the control board and the inverter module. A hum from the indoor unit is often caused by a dirty or unbalanced fan impeller, while vibration comes from loose mounts or a misaligned outdoor unit on the brackets. In case of flooding or a voltage spike, the technician tests the board, checks the inverter module, and inspects the capacitors for bulging. After a power surge, LG electronics often function only partially — the air conditioner turns on but doesn't maintain the mode, so board diagnostics are done even if the unit appears to work. This approach prevents putting the device back into operation with an already damaged module and losing it completely.
LG air conditioner owners most often ask one thing: will a specialist come to the home or will the unit have to be taken to the service center. Let's go over the workflow, what can be resolved on-site, and how free diagnostics are carried out.
Our diagnostics are free: a specialist arrives at your home within 60 minutes anywhere in the city, checks the components, and quotes the cost of work after the inspection. First, they listen to how the indoor unit behaves and compare the symptom with the code on the display, then test the circuits with a multimeter, check the line pressure and the condition of the drainage. Based on the inspection results, it's clear which component has failed: the compressor, board, sensor, or connections. The cost is quoted after diagnostics, so the owner decides based on the actual cause, not on a random price list. If the fault is obvious, repairs start on-site; if the electronics need to be disassembled, the component is taken to the service center and they explain exactly what will be checked. The technician shows where the defect is found so the decision to proceed is informed.
| Fault | Where we repair | What we check |
|---|---|---|
| Leak from indoor unit | on-site | drainage, pump |
| Refrigerant leak | on-site | line, connections |
| Fan noise | on-site | mounting, blades |
| Control board | in the service center | electronics, sensors |
| Inverter module | in the service center | power section, compressor |
We first diagnose LG control boards and repair them when possible, and only suggest replacement when repair isn't an option. In the workshop, we test the electronics circuit by circuit, check power, sensors, and power components, and compare readings with working values. A local fault — a blown capacitor, a broken trace, a failed sensor — is fixed by soldering and replacing individual components, and the board keeps working. Flooding or a voltage spike is a different story: damage affects several areas at once, and a new board turns out to be more reliable than a repaired one. The model also matters: in LG inverter units, the electronics are more closely tied to the compressor, so we check the inverter module first and only then draw conclusions about the board itself. This approach avoids replacing a working part, and the work performed and parts installed are covered by a 1-year warranty.
Winter in the capital is a factor all its own for LG air conditioners. Let's look at why units won't start when warm weather arrives, how servicing an inverter model differs from a conventional one, and which components suffer from cold and temperature swings.
After winter, an LG air conditioner often won't turn on due to icing on the outdoor unit, an electronics fault, or moisture in the connectors, and we check these causes in order. A frozen outdoor fan prevents the heat exchanger from being blown through, and condensate in the control board connectors turns into oxidation and false sensor signals when warm weather arrives. Models with anti-icing and a compressor crankcase heater have some components protected, but if the power is off during winter, the heating doesn't work and the oil in the crankcase thickens. When our technician arrives, they first clear the error from the panel, then test the circuits and check whether the fan blade turns freely. It's best not to do the first start on a frosty day — residual cold and moisture in the components interfere with a proper check, and a fault can easily be mistaken for normal operation.
An LG inverter model adds an inverter module, so diagnostics focus on the electronics, not just the compressor as in a conventional model. A conventional air conditioner starts the compressor directly from the mains, and the technician checks the windings, the starting circuit, and the pressure in the loop. In an inverter model, a module sits between the power supply and the compressor, converting the current and controlling the speed — if it fails, the motor stays silent even though it's mechanically sound. The control board and the module are connected by signal lines, and moisture in the connectors after winter breaks this connection before the compressor itself fails. We start by taking measurements at the module and checking signals from the board, and only then look at the mechanical parts. Inverter models are more sensitive to power quality and moisture, so for winter faults, checks start with the module rather than the mechanical components.
A warranty and a direct contractor are what distinguish proper service from a one-off side job. Let's look at what exactly the warranty covers, how things stand with older equipment, and why a middleman complicates accountability.
We provide a 1-year warranty on labor and parts, so if a repeat failure is our fault, we fix it under that commitment. After service, the air conditioner is stress-tested: the technician checks cooling capacity, circuit pressure, and that there are no error codes on the panel — this confirms the unit holds its mode, not just powers on. The commitment covers both parts: the work performed and the part installed. We repair LG air conditioners in Astana with the same responsibility as servicing: the warranty applies to labor and parts. Our technicians have worked with this brand for 4 to 20 years and know which components need rechecking after intervention. Coverage for parts is as important as for labor: a faulty part doesn't show up immediately, and its replacement shouldn't fall on the owner.
We also service LG air conditioners of advanced age, but after diagnostics we honestly say when restoration no longer makes sense. For such models, the condition of the compressor and electronics matters more than the year of manufacture: with a live compressor, replacing the control board brings the unit back into service, but if the power unit's resource is exhausted, the investment doesn't pay off. Diagnostics are free, so the decision is based on actual measurements, not guesswork. A technician's visit takes up to 60 minutes anywhere in the city, and after the inspection the owner gets a clear verdict: repair or replace. In my opinion, for older equipment what matters more is not the number of seasons it has seen, but how much longer the key component will last. That's why we first listen to the compressor and take readings, and only then discuss whether the work is worthwhile.
Tech Service is a direct contractor: our own technician comes to your home, not an intermediary, so one party is responsible for the work and the warranty. An aggregator's dispatcher has to pass the request to a subcontractor, and at every handoff information about which components have already been checked and replaced gets lost. With us, a specialist with 4 to 20 years of experience performs the diagnostics, does the work, and honors the commitments for a year. When you go through an intermediary, responsibility is often blurred between the dispatcher and the subcontractor, while with a direct contractor you address the same technician. You can pay via Kaspi QR, Kaspi Red, bank card, cash or bank transfer for companies, and the specialist quotes the price after free diagnostics — before work begins. If the signal returns after the intervention, the owner contacts the same place and gets a recheck without arguing over whose responsibility it is.
Diagnosing an LG air conditioner comes down to precise work: the panel signal, the symptom, and operating conditions point to a specific component. Below is a short summary to help you avoid overpaying for unnecessary work.
80brands
We work with air conditioners and split systems of every brand sold in Kazakhstan — from Almacom, Gree and Midea to LG, Samsung, Chigo and rare imported makes. Can’t find yours in the list? Call anyway — a technician will come and take a look.
Tech Service technicians repair other appliances too — with the same 1-year warranty on labour and parts.
Refrigerator Repair in Almatyfrom 3 000 ₸
Washing Machine Repair in Almatyfrom 3 000 ₸
Dishwasher Repair in Almatyfrom 3 500 ₸
Oven Repair in Almatyfrom 3 000 ₸
Cooktop Repair in Almatyfrom 3 500 ₸
Air Conditioner Repair in Almatyfrom 3 500 ₸
Boiler and Water Heater Repair in Almatyfrom 2 500 ₸
Freezer Repair in Almatyfrom 6 000 ₸
Tumble Dryer Repair in Almatyfrom 5 000 ₸
Coffee Machine Repair in Almatyfrom 2 500 ₸
Robot Vacuum Cleaner Repair in Almatyfrom 3 500 ₸
Vacuum Cleaner Repair in Almatyfrom 1 500 ₸
Microwave Oven Repair in Almatyfrom 2 000 ₸
Hair Dryer Repair in Almatyfrom 1 500 ₸
Iron Repair in Almatyfrom 3 000 ₸
Electric Kettle Repair in Almatyfrom 2 500 ₸
Mixer Repair in Almatyfrom 2 500 ₸
Multicooker Repair in Almatyfrom 500 ₸
Air conditioner errors are codes on the display or flashing indicators that show which component has failed.
5 March 2026 · 12 minutes read
If your air conditioner is leaking, first turn it off and cut the power, place a container under the drip, and move any wiring away from the water.
19 October 2025 · 12 minutes read
Gas boiler errors are codes on the display or a flashing indicator that point to a specific component: ignition, pressure, draft, sensor, or control board.
10 February 2026 · 11 minutes read