Семён Ш.Order No. AST-2512-345 · 23 August 2025
oursДамир М отсоветовал дорогой ремонт, предложил простой. Обошлось заменой: плата. Тихо, ровно, без сюрпризов)
City
Language
What broke
Sections
Message on WhatsApp+7 (778) 746 00 26Mon–Fri 10:00–19:00, Sat–Sun 11:00–18:00
We'll get your split system running again on site. 1-year warranty on labor and parts.
Our own technicians4 to 20 years of experience




Repair prices
Below are typical symptoms that Beko owners report. The technician determines the exact cause on site.
refrigerant leak, compressor wear
from10 000 ₸
clogged drain, cracked drain pan
from6 500 ₸
dead remote batteries, no power, control board failure
from14 000 ₸
fan impeller imbalance, loose fasteners
from8 000 ₸
dirty filter, buildup on evaporator
from6 500 ₸
displaced drain hose, clog
from6 500 ₸
clogged filter, fan malfunction
from13 500 ₸
compressor overheating, control board failure
from14 000 ₸
The table lists the 'from' price for labor, for common jobs also the 'from' price of the part, plus the time required to complete the job.
1–2 hourstime
from 8 500 ₸cost

BeforeAfter5 steps

From request to checking the unit's operation after repair.
Describe the symptoms by phone or messenger so the technician brings the right tools.
The technician explains what will be replaced and quotes the price before disassembling the unit; ask about parts.
Confirm a convenient visit time and scope of work so the technician arrives prepared.
The technician runs cooling and heating modes, checks drainage and noise in the first minutes.
Ask how often to clean the filters and when to schedule the next service.
We reply during working hours
If the unit isn't cooling, leaking, or noisy, don't delay. Describe the symptoms and the technician will determine the cause.

Warranty question? Call us
+7 (778) 746 00 266 127 reviews of repairs at TECH SERVICE in total
Семён Ш.Order No. AST-2512-345 · 23 August 2025
oursДамир М отсоветовал дорогой ремонт, предложил простой. Обошлось заменой: плата. Тихо, ровно, без сюрпризов)
Юрий М.Order No. TSA-86858 · 30 March 2024
oursНикита М провозился, но сделал. Выбрал techservice, потому что близко к работе. Третий месяц — никаких проблем)
Маргарита П.Order No. AST-2304-733 · 8 June 2023
oursПозвонил насчёт сплит-системы. Основная жалоба — не холодит. Замена: компрессор. Цену держали до конца, молодцы. Мастер сам предложил забрать технику на следующий день. Крутит ровно, без рывков.
Василий Е.Order No. 69402 · 29 March 2022
oursПозвонил в четыре места, тут ответили по-человечески. Открыл — и сразу понял: течёт. Дамир М всё сделал при мне, за пятнадцать минут. Выдали номер заказа и сказали, как отслеживать. Нагрев в норме, посторонних звуков нет.
Григорий И.Order No. AS-2376 · 12 October 2021
oursС левого берега ехать далеко, поэтому искал поближе к дому. Ходил вокруг него три дня, потом плюнул и повёз. Больше всего мешало: ошибка. Шум ушёл, работает мягко.
Оксана Т.Order No. AS-2569 · 13 December 2020
oursЗимой без техники никак, поэтому тянуть было нельзя. Ни с того ни с сего — наледь. Дамир М отсоветовал дорогой ремонт, предложил простой. Вернули — проверил, всё ок.
Альмира П.Order No. AS-3646 · 12 January 2020
oursӘйелім «таста» деді, мен көрсетуді жөн көрдім. Мастер бәрін түсіндірді. Ақауын тез анықтады, қажетсіз нәрсе ұсынбады. Жұмысты сол күні аяқтады. Ескі бөлшекті көрсетіп, қайтарып берді. Қайта жүгінуден тартынбаймын)
Валерий Д.Order No. AST-1904-431 · 4 December 2019
oursДруг из Сарыарки посоветовал это место. Первое, что заметил: не включается. Проверил на всех режимах — держит.
Олег Х.Order No. 55752 · 30 December 2018
oursДруг из Сарыарки посоветовал это место. Заявку оставил на всякий случай, а зря время тянул. Проблема ровно одна: течёт. Сначала думал, что нужен паспорт, но обошлось. Гудит ровно, не перегревается.
Фариза Л.Order No. TSA-39229 · 31 October 2017
oursҚұрылғы ескі, бірақ жақсы қарайды екен. Екі күнен кейін өзі қоңырау шалды. Келесіде де осында келемін.
experience10 yearsAir conditioner refill technician
experience2 yearsAir conditioner cleaning technician
experience14 yearsAir conditioner chemical cleaning specialist
experience15 yearsMobile air conditioner technician
experience15 yearsLead HVAC specialist
Didn’t find the answer? Message us on WhatsApp.
Ask a questionFirst, replace the batteries in the remote and check if the mode has changed. If the remote works but the unit doesn't respond, the signal receiver or circuit board may be faulty — a technician's diagnostics is needed.
Check the power supply and the circuit breaker in the panel, and make sure the unit isn't still in winter mode. If there's no power and the remote doesn't respond, there may be issues with the board or capacitor — diagnostics is needed.
If the unit blows weak cold air and frost appears on the pipes, it's usually a refrigerant leak, not the compressor. The technician makes the final call after measuring pressure and inspecting the circuit.
Yes, during repair, with your approval, the technician washes the indoor unit and drain to eliminate odors and clogs. Antibacterial treatment and maintenance are ordered separately, depending on the unit's condition.
It depends on the model and the nature of the breakdown: if the windings are worn or the compressor is seized, it's usually replaced, while some starter faults can be fixed with repair. The technician decides after diagnostics.
Yes, sharp temperature swings and severe frosts put stress on the compressor, board, and refrigerant circuit connections. That's why leaks and electronics failures are more common in spring, especially without maintenance.

Author: Erlan Zh.,Air conditioner refill technician
Published
Updated
Tech Service repairs Beko air conditioners in Astana as a direct contractor: our technician comes to your home or takes the unit to our service center. Diagnostics are free, we arrive within 60 minutes anywhere in the city, and you get a 1-year warranty on labor and parts. The technician gives you the price after diagnostics.
Weak cooling, water on the wall under the indoor unit, and humming when it starts up are the three most common reasons Beko owners call us. Here's the logic of symptom → component → what the technician does, so you understand the cause before the specialist arrives.
With Beko, leaks are almost always related to the drainage system — a clogged drain, a displaced tube, or evaporator freezing due to low refrigerant. Moisture accumulates in the drain pan, overflows, and runs down the wall instead of going into the drain. On models with a drain pump, there's another cause — pump failure, and then water appears even with a clean drain. Inspect the evaporator for an ice layer: if the heat exchanger is frozen, condensate doesn't drain properly and drips past the pan. Beko air conditioner repair in Astana starts with free diagnostics: we disassemble the indoor unit, check the drain slope and circuit pressure, and don't just blow out the tube. If water returns a week after cleaning the drain, the cause isn't a clog but heat exchanger freezing — the technician checks the circuit pressure instead of just blowing out the tube again.
Noise and vibration in Beko units usually come from the indoor fan and outdoor unit imbalance, while failure to start after winter is often due to the start capacitor or a frozen compressor. The fan blade gets covered in dust over time, loses balance, and starts humming at medium speeds, and the outdoor unit vibrates if the mounting brackets are loose. The start capacitor is a wear item: it loses capacitance, and the compressor hums but won't start. After a power outage, the air conditioner may not turn on due to a board reset — before taking the unit to service, check that the breaker isn't tripped and the remote is sending a signal. Our technician arrives anywhere in the city within 60 minutes and identifies the cause on site, and we provide a 1-year warranty on labor and parts for any repair performed.
Beko self-diagnostics display a code on the indoor unit when the board detects a deviation in component operation. Here's how to read such a combination and what it tells the technician.
Beko displays the code as an alphanumeric combination on the indoor unit display or by a flashing indicator — the code points to a specific component, not a complete failure. On models without a screen, self-diagnostics shows itself as a series of light flashes: the number of long and short signals adds up to the same combination as on the display. The control board reads this record from temperature sensors, communication between units, and compressor protection, so the same combination on different series may refer to different circuits. Take a photo of the screen or record the flashing on video and save it until the technician arrives — using this record, they'll bring the right sensors, board, and coils instead of guessing and wasting time on repeat diagnostics.
| Code group | What it indicates | What the technician checks |
|---|---|---|
| Temperature sensor | Open or short circuit in the air or pipe sensor | Sensor resistance, connector on the board |
| Unit communication | No data exchange between units | Inter-unit cable wiring, contacts |
| Compressor protection | Overheating, overcurrent | Start-up components, windings, current draw |
| Fan | Motor stop or failure | Impeller, winding, Hall sensor |
| Four-way valve | Mode switching failure | Valve coil, power supply to it |
Beko boards are more often repaired than replaced — for typical failures, it's enough to replace the failed component rather than the entire module. The Beko control board manages modes and fans, receives signals from temperature sensors, and communicates with the outdoor unit, so its failure affects several functions at once. The technician first checks the terminal connections and wiring: an oxidized contact produces the same symptoms as a burned-out component but is faster to fix. If the board is flooded or burned after a power surge, restoration may not be practical — the technician assesses the condition of the traces and decides based on the actual state, not the code name. A 1-year warranty on labor and parts applies even after module restoration.
We walk through the process from request to warranty and explain what determines whether the air conditioner is repaired on-site or at the service center, and what the specialist checks on site.
| Failure | Where it's fixed | What the specialist does |
|---|---|---|
| Refrigerant leak | On-site | Finds the leak, solders the circuit, recharges |
| Clogged drainage | On-site | Clears the tube, washes the drain pan |
| Faulty fan | On-site | Replaces the motor or impeller |
| Start capacitor | On-site | Checks the circuit, installs a new component |
| Control board | More often at the service center | Removes the board, diagnoses and repairs it |
| Compressor | More often at the service center | Assesses the component, removes it if necessary |
During the free diagnostics, the technician checks the pressure in the circuit, the electrical circuits and the board, the drainage and the operation of the fans — and based on the results, names the cause and the cost of the work. Beko air conditioner repair in Astana starts with exactly this on-site inspection. Pressure testing of the circuit shows whether the system holds pressure or the refrigerant is escaping through a microcrack. Checking the electrical circuits reveals wear on the start capacitor, a broken motor winding, and power supply failures on the board. The drainage is tested by pouring water through it, and the fans are listened to and checked for rotation under load. The inspection is free regardless of whether you agree to the work or not — so you won't have to pay for a check if the breakdown is minor. In my opinion, it is the on-site inspection that distinguishes the real cause from a symptom: the same weak cooling can be caused by both a refrigerant leak and a clogged filter.
In Astana's climate with frosts and sharp temperature swings, equipment operates at its limit, so maintenance matters more than it seems. We explain when refrigerant charging is needed, why the indoor unit should be cleaned, and how often to carry out maintenance.
Beko air conditioner repair in Astana begins with finding the leak: a lack of refrigerant in a Beko unit shows up as weak cooling, freezing of the heat exchanger, and the compressor running without pauses. The unit blows warm air, frost appears on the pipes and the evaporator, and the outdoor unit hums continuously without shutting off. Charging is required only after the leak has been found and fixed: refrigerant itself is not consumed, it escapes through cracks in the pipes, loose connections, or a damaged circuit. First, the technician performs a pressure test, locates the leak, vacuums the system, and only then adds gas by weight. A lack of refrigerant causes freezing of the heat exchanger, and this symptom can easily be confused with a clogged capillary. Charging refrigerant without pressure testing is pointless — if the leak hasn't been found, the gas will escape again, and a repeat procedure will cost more than finding the cause.
In Astana's climate with frosts and temperature swings, Beko maintenance is done twice a year — before the cooling season and before winter. Spring servicing prepares the unit for the heat: cleaning the heat exchanger and checking the refrigerant pressure reduce the risk of overheating of the on/off compressor, which runs at constant speed and without pauses. Autumn preparation is more important than spring — if the outdoor unit is not protected from icing, the compressor wears out in a couple of seasons instead of its design life. In winter, condensate in the drainage freezes and bursts the pipes, and thickened compressor oil accelerates wear of the friction pairs at startup. The technician checks the drainage slope, the condition of the thermal insulation, and the operation of the anti-icing system so that the equipment survives the cold without repair. City residents should book autumn maintenance in advance.
Beko air conditioner repair depends on the type of compressor and operating conditions: inverter models are designed differently from conventional ones, and frosty winters impose their own requirements on the outdoor unit. We explain what an owner should know before calling a technician.
The Beko inverter adjusts compressor speed smoothly and requires checking the board and inverter module, while a standard on/off unit runs at constant speed and more often suffers from a start capacitor. An inverter unit maintains the set temperature without abrupt starts and stops, so its lifespan is longer — but diagnostics are more complex: the technician checks the power module, sensors, and windings separately, and sometimes the entire compressor power circuit from connector to connector. In conventional models, the typical cause of failure is a worn start capacitor, which is replaced separately without touching the compression unit itself; it's also worth checking the thermal relay, which wears out from frequent overloads. Inverter models are more sensitive to voltage surges — if power outages are regular, check the power stabilization, not just the air conditioner itself.
In winter, the Beko outdoor unit operates in severe frost and temperature swings, which takes a toll on the compressor, four-way valve, and heat exchanger icing. The four-way valve switches the air conditioner between cooling and heating, and constant heating operation in frost wears it out faster: moving parts lose their seal, and the mode stops switching cleanly. Icing of the outdoor unit's heat exchanger reduces heat transfer and forces the compression unit to work under overload, and the defrost system doesn't always manage to remove ice during sudden weather changes. In winter, the temperature difference between day and night in the capital reaches tens of degrees, adding extra stress on metal and seals. If the air conditioner is used for heating in winter, compressor wear accelerates — maintenance and protection of the outdoor unit extend service life more noticeably than fixing a breakdown after it happens.
Putting together the symptoms, error code, and work sequence gives the Beko owner a clear picture: what to check themselves, when to call a technician, and what to look for when choosing a contractor.
80brands
We work with air conditioners and split systems of every brand sold in Kazakhstan — from Almacom, Gree and Midea to LG, Samsung, Chigo and rare imported makes. Can’t find yours in the list? Call anyway — a technician will come and take a look.
Tech Service technicians repair other appliances too — with the same 1-year warranty on labour and parts.
Refrigerator Repair in Almatyfrom 3 000 ₸
Washing Machine Repair in Almatyfrom 3 000 ₸
Dishwasher Repair in Almatyfrom 3 500 ₸
Oven Repair in Almatyfrom 3 000 ₸
Cooktop Repair in Almatyfrom 3 500 ₸
Air Conditioner Repair in Almatyfrom 3 500 ₸
Boiler and Water Heater Repair in Almatyfrom 2 500 ₸
Freezer Repair in Almatyfrom 6 000 ₸
Tumble Dryer Repair in Almatyfrom 5 000 ₸
Coffee Machine Repair in Almatyfrom 2 500 ₸
Robot Vacuum Cleaner Repair in Almatyfrom 3 500 ₸
Vacuum Cleaner Repair in Almatyfrom 1 500 ₸
Microwave Oven Repair in Almatyfrom 2 000 ₸
Hair Dryer Repair in Almatyfrom 1 500 ₸
Iron Repair in Almatyfrom 3 000 ₸
Electric Kettle Repair in Almatyfrom 2 500 ₸
Mixer Repair in Almatyfrom 2 500 ₸
Multicooker Repair in Almatyfrom 500 ₸
Air conditioner errors are codes on the display or flashing indicators that show which component has failed.
5 March 2026 · 12 minutes read
If your air conditioner is leaking, first turn it off and cut the power, place a container under the drip, and move any wiring away from the water.
19 October 2025 · 12 minutes read
Gas boiler errors are codes on the display or a flashing indicator that point to a specific component: ignition, pressure, draft, sensor, or control board.