Ырысгуль Н.Order No. AS-7022 · 29 July 2026
oursТелефонмен кеңестім, кейін апардым. Бағаны алдын ала айтты, соңында өзгермеді. Түскі үзіліске қарамастан қабылдады. Жұмыс істеп тұр, шағым жоқ
City
Language
What broke
Sections
Message on WhatsApp+7 (778) 746 00 26Mon–Fri 10:00–19:00, Sat–Sun 11:00–18:00
A technician arrives within 60 minutes anywhere in the city. Diagnostics are free.
Our own technicians4 to 20 years of experience




Repair prices
Symptoms help the technician bring the right tools and parts in advance. Below are typical signs and likely components.
refrigerant leak, filter, compressor
from10 000 ₸
clogged drain, unit misalignment
from6 500 ₸
power, board, remote
from14 000 ₸
fan, mounting, compressor
from13 500 ₸
points to a specific component
from14 000 ₸
clogged filter, fan, leak
from10 000 ₸
refrigerant leak, compressor, board
from10 000 ₸
overheating, sensor, board
from8 500 ₸
The table lists the 'from' price for labor, for common jobs also the 'from' price of the part, plus the time required to complete the job.
1–2 hourstime
from 8 500 ₸cost

BeforeAfter5 steps

Five steps from the call to checking the air conditioner's operation.
Describe the symptom and air conditioner model so the technician brings the right tools.
The technician arrives anywhere in the city within 60 minutes of the request.
The technician clarifies by model and component which parts and work will be needed.
The technician needs clear access to the indoor and outdoor units and space for tools.
The technician records the work performed and advises which settings to change.
We reply during working hours
Choose a convenient request channel and provide the air conditioner model so the technician arrives prepared.

Warranty question? Call us
+7 (778) 746 00 266 127 reviews of repairs at TECH SERVICE in total
Ырысгуль Н.Order No. AS-7022 · 29 July 2026
oursТелефонмен кеңестім, кейін апардым. Бағаны алдын ала айтты, соңында өзгермеді. Түскі үзіліске қарамастан қабылдады. Жұмыс істеп тұр, шағым жоқ
Софья Ц.Order No. AS-5427 · 7 July 2026
oursПозвонил в четыре места, тут ответили по-человечески. Первое, что заметил: не холодит. Ни шума, ни запаха, всё штатно
Анастасия Т.Order No. 16684 · 12 February 2026
oursС этим и пришёл: не холодит один блок. Дамир М объяснял без умных слов, за это спасибо. Работает, как будто и не ломалось
Иван Н.Order No. AS-3475 · 1 September 2024
oursБольше всего мешало: не холодит один блок. Никита М — мастер от бога, если можно так сказать. Внешне не видно, что разбирали.
Иван Н.Order No. AST-2409-792 · 4 May 2024
oursХотел вызвать на дом, но в ЖК не пускают без пропуска. Позвонил жене, говорит: не включаеться. Работает, как будто и не ломалось.
Эвелина Ш.Order No. ZK-2022-513 · 14 September 2022
oursПервое, что заметил: не холодит один блок. Никита М отсоветовал дорогой ремонт, предложил простой. Крутит ровно, без рывков!!
Юрий М.Order No. AST-2202-510 · 3 June 2022
oursИскал, кто роботает в субботу, у нас с женой график сложный. Диагностика мобильного кондиционера — с неё и начал. Основная жалоба — не холодит. Дамир М посмотрел и честно сказал: менять не надо. Вышло из строя: дренаж. Сказали, что позвонят, и действительно позванили. Вернули — проверил, всё ок
Валерий Д.Order No. TSA-91674 · 7 February 2020
oursРаньше обращался в другой сервис, там очередь на две недели. С чем обратился: не включается. Пользуюсь и вспоминаю добрым словом.
Валентина Р.Order No. 1805-5375 · 24 June 2018
oursДруг из Сарыарки посоветовал это место. С этим и пришёл: не холодит. Никита М отсоветовал дорогой ремонт, предложил простой. Нагрев в норме, посторонних звуков нет!!
Ярослав С.Order No. 65542 · 2 July 2017
oursЗаявку оставил через сайт вечером, утром перезвонили. Симптом как на ладони: ошибка. Функционирует, тьфу-тьфу.
experience10 yearsAir conditioner refill technician
experience2 yearsAir conditioner cleaning technician
experience14 yearsAir conditioner chemical cleaning specialist
experience15 yearsMobile air conditioner technician
experience15 yearsLead HVAC specialist
Didn’t find the answer? Message us on WhatsApp.
Ask a questionA blinking indicator on a Panasonic usually means the unit is running a self-diagnostic: the issue could be a sensor, the control board, or the compressor. A technician can decode the error code and find the cause after free diagnostics.
Most faults in Panasonic inverter models can be fixed on-site by a technician. If the compressor needs replacing or the board requires complex repair, a service center may be needed. Diagnostics are free, and the technician will advise you on the best option.
Panasonic has its own error codes and design features, especially in inverter and multi-split systems. A technician needs to know this brand to diagnose the fault correctly and source the right parts.
Code H11 on a Panasonic relates to a communication failure between the indoor and outdoor units. The exact cause—wiring, control board, or interference—will be determined by a technician on-site after free diagnostics.
It depends on the model and the extent of the damage: sometimes a Panasonic board can be repaired, but with serious defects it is replaced entirely. The technician decides after diagnostics and coordinates with you.
Yes, we provide a 1-year warranty on labor and parts. This also covers Panasonic compressor replacement if diagnostics show it's needed.

Author: Erlan Zh.,Air conditioner refill technician
Published
Updated
Tech Service repairs Panasonic air conditioners in Astana as a direct contractor, not an aggregator. Our technician arrives within 60 minutes anywhere in the city or accepts the unit at our service center. Diagnostics are free, and you get a 1-year warranty on labor and parts. The technician gives you the price after diagnostics.
A blinking indicator and a code on the display are not a death sentence—they're hints from the unit itself. Let's look at what Panasonic split systems signal and what you can realistically do before the technician arrives.
| Code | What it means | What we check |
|---|---|---|
| H11 | Communication failure between indoor and outdoor units | Cable, terminals, outdoor unit board |
| H12 | Control line communication error | Wiring between units, interference |
| F11 | Heat exchanger sensor fault | Sensor resistance, connector |
| H99 | Overload protection triggered | Compressor current, outdoor fan |
| F91 | Inverter module error | Power transistors, board capacitors |
In our experience, the most common causes are a refrigerant leak, a clogged filter, or an inverter module failure. You can only tell them apart on site by checking line pressure and compressor current. The fan blows air, but the heat exchanger doesn't absorb heat if pressure in the refrigerant line has dropped or the compressor isn't reaching operating mode. Clogged air filters create a similar picture: there's airflow but weak cooling because air barely passes through a dusty coil. An inverter module failure looks different—the outdoor unit starts for a few seconds and then stops. If the fan blows but there's no cold, don't top up refrigerant "by eye"—without finding the leak, it will escape again, and the compressor will wear out. In such cases, Panasonic AC repair in Astana starts with finding the leak and checking the inverter module, not with recharging.
Most often, the cause is a clogged drain system or a frozen heat exchanger, which prevents condensate from draining through the pipe and makes it drip onto the wall. The drain system removes moisture from the indoor unit by gravity or a pump, and if the pipe gets clogged with dust and slime, water overflows the drain pan. A frozen coil has the same effect: ice on the heat exchanger melts unevenly, and the volume of condensate exceeds the drain capacity. In winter, condensate on the line adds to this if it's poorly insulated. Before the technician arrives, just turn off the AC and place a container under the drip, but don't disassemble the unit yourself—you could damage the drain pump. If water keeps pouring and doesn't stop after turning off, it's best to wait for a specialist and not touch the drain pan or pipe until inspection.
Inverter, multi-split, and ducted Panasonic systems are more complex than a standard split, and not every technician takes on such equipment. Here's what to know before calling.
In inverter models, we check not only the compressor but also the inverter module and control board, because they set the rotation speed and are the most common points of failure. The Panasonic inverter compressor doesn't run at constant speed; it smoothly varies power through the module that converts the supply voltage. The module and control board are interconnected, and a fault in this pair shows up as a failure to start, jerking during operation, or an error code on the display. A conventional compressor can be tested directly, but an inverter one must not be started without diagnosing the module — an error in the control circuit can damage the compressor itself. In practice, a failure to start is often caused by the module rather than the unit itself.
In our experience, this symptom more often points to a fault in a specific indoor unit or its connection to the outdoor unit rather than a breakdown of the entire system, so we diagnose each unit separately. In Panasonic multi-split configurations, one outdoor module serves several indoor units, and each is connected to it by its own refrigerant line. The indoor unit's control board transmits data to the common controller, so a communication failure or a clog in one line shuts down only that zone. If you disconnect the faulty indoor unit, the others keep working — this helps localize the problem before disassembling the outdoor module. Tech Service services Panasonic multi-split systems and starts by polling each unit in turn rather than taking apart the outdoor unit.
We start Panasonic air conditioner work in Astana with free on-site diagnostics and only then quote the price. Here's what the technician does at each stage and why the sequence doesn't change.
We first try to repair the Panasonic control board, and only if the damage is irreversible do we suggest replacing the unit. For local damage to the traces, a blown relay, or a dried-out capacitor, soldering is justified: the unit goes back into service, and the owner keeps the original board with its verified firmware. The inverter module is a different story: when the power transistors are burned out, repair often requires parts that cost more than a new unit, and then replacement is more honest in terms of time and reliability. Panasonic air conditioner repair in Astana for electronics usually comes down to repairing the unit rather than replacing it. In practice, electronics issues are often resolved by repairing the unit, not replacing it. Before agreeing on the work, we explain to the owner what exactly failed and why we chose this option. This approach saves the owner money and preserves the original electronics of the unit.
Our technician looks at the pressure in the circuit and the compressor current: if the pressure drops while the compressor runs normally, it's a leak, not a failure of the unit itself. The opposite picture — pressure is normal but current is high or the compressor hums and shuts off on protection — points to wear in the mechanical part. We search for refrigerant leaks at joints, flare fittings, and service ports, check with soap bubbles and a leak detector, and inspect the line for abrasions. Refilling with refrigerant without this procedure is pointless: the gas will escape again through the same spot, and you'll call the technician again in a month. So we first find and fix the leak, vacuum the circuit, and only then charge the system by weight while monitoring superheat.
A sharply continental climate with frosts down to −35 °C imposes its own limits on air conditioner operation. Let's look at how low temperatures affect the maintenance and repair of Panasonic split systems.
Radiator icing in winter is most often due to heating mode in severe frost or a lack of refrigerant, which causes the heat exchanger to overcool. In heating mode, the outdoor unit works as an evaporator: condensate on the fins freezes, and ice gradually blocks the airflow. Due to a refrigerant leak, the pressure in the circuit drops, the boiling temperature shifts down, and the heat exchanger gets coated with ice even with working automation. The four-way valve switches between cooling and heating modes, and if it sticks in an intermediate position, it speeds up icing. The indoor unit fan blows air through the ice-clogged circuit and barely changes the room temperature. If you don't defrost the unit in time, ice will deform the heat exchanger fins and damage the fan, so it's best not to ignore icing. Panasonic air conditioner repair in Astana in winter most often starts with such iced-up units.
The cause is usually the four-way valve, the crankcase heater, or a temperature sensor that blocks the compressor from starting in heating mode in frost. The valve reverses the refrigerant flow between circuits, and if it sticks, the system stays in cooling mode — the compressor starts but doesn't deliver heat to the room. The crankcase heater warms the compressor crankcase and the outdoor unit drain pan, and if the coil breaks, the automation prevents startup to avoid pumping thick oil through the circuit. Outdoor air and heat exchanger temperature sensors take readings that the board uses to decide on startup; resistance drift in the cold shifts the activation threshold. You shouldn't turn on heating outside in extreme frost without checking the model's specified limits — this is compressor protection, not a breakdown.
If your fridge cools worse after cleaning, it's often because the sensor got knocked out of place, the filter isn't secured properly, or the drain tube was damaged during disassembly. The technician removes the housing and takes out the air filters, and during reassembly the heat exchanger temperature sensor can easily shift by a couple of centimeters — the board gets wrong readings and shuts off the compressor too early. A poorly seated filter lets air bypass the coil, the heat exchanger freezes unevenly, and the drain system with a misaligned tube starts leaking inside the unit. A damaged housing seal diverts airflow around the evaporator, and the cold simply doesn't reach the room. Cleaning shouldn't change how the system works, so if it got worse afterward, that's a reason to check the reassembly, not to top up the refrigerant.
When a breakdown happens, three things matter: how fast a specialist arrives, what the estimate is made of, and who's responsible for the result. Here's how booking, payment, and warranty work with a direct contractor.
We provide a 1-year warranty on labor and parts because Tech Service is a direct contractor with its own specialists, not an aggregator that shifts responsibility to third-party subcontractors. Behind every Panasonic repair in Astana is a specific person with 4 to 20 years of experience, and they're the one accountable to the owner for the result. The warranty covers both replaced components and the procedure itself: if a fault returns due to our work, we fix it under warranty. The direct model is convenient because if you need us again, you don't have to search for a contractor and prove who did the job. A warranty from a direct contractor means that if something breaks again, you return to the same service rather than looking for a new one.
We arrive within 60 minutes anywhere in the city, and the specialist comes to your home or takes the equipment to the service center — whichever is more convenient for the client. To book, just describe the symptom or give the error code: that way the technician knows in advance what system they're dealing with — inverter or conventional. On-site diagnostics are free, so the owner immediately understands the nature of the fault instead of paying for the inspection itself. If the work can be done on-site, it's performed in front of the client; if the unit needs to be disassembled, we repair it at the service center. The sooner you call a specialist at the first symptoms, the lower the risk that a minor fault leads to compressor failure. If the indicator is flashing or a code appears, mention it when booking — the technician will bring the necessary parts and tools right away.
Here's what really determines the outcome of a Panasonic air conditioner repair: what the accuracy of the diagnosis depends on, why checking the electronics matters, and how the local climate plays a role.
80brands
We work with air conditioners and split systems of every brand sold in Kazakhstan — from Almacom, Gree and Midea to LG, Samsung, Chigo and rare imported makes. Can’t find yours in the list? Call anyway — a technician will come and take a look.
Tech Service technicians repair other appliances too — with the same 1-year warranty on labour and parts.
Refrigerator Repair in Almatyfrom 3 000 ₸
Washing Machine Repair in Almatyfrom 3 000 ₸
Dishwasher Repair in Almatyfrom 3 500 ₸
Oven Repair in Almatyfrom 3 000 ₸
Cooktop Repair in Almatyfrom 3 500 ₸
Air Conditioner Repair in Almatyfrom 3 500 ₸
Boiler and Water Heater Repair in Almatyfrom 2 500 ₸
Freezer Repair in Almatyfrom 6 000 ₸
Tumble Dryer Repair in Almatyfrom 5 000 ₸
Coffee Machine Repair in Almatyfrom 2 500 ₸
Robot Vacuum Cleaner Repair in Almatyfrom 3 500 ₸
Vacuum Cleaner Repair in Almatyfrom 1 500 ₸
Microwave Oven Repair in Almatyfrom 2 000 ₸
Hair Dryer Repair in Almatyfrom 1 500 ₸
Iron Repair in Almatyfrom 3 000 ₸
Electric Kettle Repair in Almatyfrom 2 500 ₸
Mixer Repair in Almatyfrom 2 500 ₸
Multicooker Repair in Almatyfrom 500 ₸
Air conditioner errors are codes on the display or flashing indicators that show which component has failed.
5 March 2026 · 12 minutes read
If your air conditioner is leaking, first turn it off and cut the power, place a container under the drip, and move any wiring away from the water.
19 October 2025 · 12 minutes read
Gas boiler errors are codes on the display or a flashing indicator that point to a specific component: ignition, pressure, draft, sensor, or control board.
10 February 2026 · 11 minutes read